3) FUNCTIONING AND OPERATIONS TO CARRY OUT DURING PROGRAMMING
Dip-switch 1 ON : to arm > reset input free – to disarm > positive closed to reset input
Dip-switch 1 OFF : to arm >reset input free – to disarm > negative (GND) closed to reset input
Dip-switch 2 ON : the alarm memory LED is visible when the receiver is disarmed and reset itself at the following arming – OFF=memory not
active
Dip-switch 3 ON : the built-in buzzer indicates arming (BEP-BEP-BEP) and disarming (BEP) and the events Tamper – Battery – Supervision –
Scanner with additional 5 BEP while arming and disarming – OFF = buzzer not active
Dip-switch 4 ON : after an alarm the relays 1-12 switch also in disarmed condition – OFF = they switch only in armed condition
Dip-switch 5 ON : after an alarm coming from whatever line, the relay contact 12 opens for approx. 2 seconds ("OR" function of the alarms -
see drawings).
Dip-switch 6 : not used
4) FUNCTIONING OF RELAY OUTPUTS:
The 16 free contacts are NC and temporarily open in case of alarm (for 2 seconds). In this configuration the LED of the programming zone
flashes slowly By pressing once SW 3 the output becomes NO and closes for 2 seconds in case of alarm: the LED flashes quickly. By pressing
again SW 3 the output becomes NO and closes for 3 minutes: the LED light remains on.
While programming the remote controls PCK (red and green buttons) the relay output is always bistable (green=open – red=closed).
While programming the Sensor door/window contacts with "open door" warning option, the relay follows the opening or closing of the
door/window (i.e. it remains open if the door/window remains open).
5) ALARM SITUATIONS (they are always temporarily displayed or stored by the relevant LEDs)
Alarm from detectors: an alarm transmission from a detector switches the relevant relay according to programming
Tamper: the opening of the receiver and/or the transmission of tamper on detectors always switch the "tamper" relay
Low battery: this transmission always switches the "battery" relay
Supervision: unsuccessful supervision signals always switch the relevant relay latest after 8 hours from the event
Antiscanner: possible radio noises which inhibit the correct receiving on both frequencies always switch the relevant relay
6) FIRST PROGRAMMING
This operation takes place through self-learning, by preparing the R-Evolution 12 to receive the detector transmission on a selected zone and by
carrying out the transmission itself. It is possible to program all Silentron detectors and/or remote controls. The programming remain stored even
after disconnecting power supply: it can be cancelled only with a "reset" operation.
Total reset: supply the receiver while open and press S1 for 10 seconds: a "beep" confirms the complete cancellation of existing programming.
LED 1 flashes, waiting for programming of the first detector.
Programming of first detector: select the requested output functioning (see 4) and put the battery inside the detector. One "bep" confirms that
programming has been successful, 3 "bep" indicates that the detector was already programmed.
Programming of further detectors: change zone by pressing the S2 button and go on as described above.
Programming of remote controls: choisir le groupe désiré en appuyant plusieurs fois sur la touche S2. En appuyant simultanément sur les
touches rouges et vertes, un fonctionnement bistable est obtenu (ROUGE : ON - VERT :OFF). En appuyant sur une touche jaune ou bleue
pendant 10 secondes, est obtenue une commande monostable temporisée de 2 secondes ou 3 minutes selon le type de programmation (voir
paragraphe 4). Un BEEP confirme la programmation effectuée.
End of programming: when programming is finished, press together S1 and S2. Warning: if you do not press any button or no transmissions
are sent for 1 minute, programming is automatically ended.
NOTE: in the channels where remote controls and/or keypads have been programmed, it is not possible to program any detector
7) CANCELLATION / MODIFICATION OF PROGRAMMING
For such operations it is necessary to open the receiver, after stopping the tamper warning sent to the control panel, and press S1 to enter
programming mode. To cancel a detector / remote control of a zone it is necessary to select the zone and press S2 , then S1 for 10 seconds
(you hear a confirmation "bep"). To add a detector / remote control, select the requested zone and let the detector /remote control send the
transmission code.
8) EVENTS SIGNALLING (during normal functioning) Every alarm is temporarily signalled by the LEDs, therefore the system testing is
immediate: for example in case of alarm of detector no. 5 the LED no. 5 will be flashing; or in case of low battery of detector no. 5 again, both
LED no.5 and the battery LED will be flashing, and so on.
Warning: at every arming/disarming of control panel, the receiver signals with 5 "bep" (see point 3 – dip-switch 3) the events which have taken
place during the last armed / disarmed period: this signalling should not be ignored, because it could cause a failure in the functioning of the
system or of parts of it. If the buzzer is excluded as requested by the end user, the installer has the responsibility to carry out all the necessary
connections so that signals of low battery, tamper, scanner or lack of supervision will be sent through the proper relay outputs connected to the
control panel.