Incandescent / Halogen
120 V Dimmer
Rated at 120 V
60 Hz 600 W
S-600PE, S-603PE
Important Notes
Please read before installing.
1. CAUTION: Use only with permanently-installed 120 V
fixtures. To avoid overheating and possible damage to other equipment, do not
use to control receptacles, fluorescent lighting fixtures, motor-driven appliances,
or transformer-supplied appliances.
2. Install in accordance with all national and local electrical codes.
3. Only one dimmer can be used in a 3-way circuit.
4. With the Eco-Dim
switch set to "Eco", the lights are slightly dimmed at the
TM
highest light level for 15% energy savings. With the switch set to "Normal", the
dimmer will provide normal energy savings. In either mode, dim down further for
more savings.
5. When no "grounding means" exist within the wallbox then the NEC
Article 404.9 allows a dimmer without a grounding connection to be installed as
a replacement, as long as a plastic, non-combustible wallplate is used. For this
type of installation, cap or remove the green ground wire on the dimmer and use
an appropriate wallplate such as Lutron's Claro
series wallplates.
®
6. For new installations, install a test switch before installing the dimmer.
7. Protect dimmer from dust and dirt when painting or spackling.
8. Recommended minimum load is 40 W
9. It is normal for the dimmer to feel warm to the touch during operation.
10. Clean dimmer with a soft damp cloth only . Do not use any chemical cleaners.
Multigang Installations
When installing more than one control in the same
wallbox, it may be necessary to remove all inner side
sections prior to wiring (see diagram). If pre-installed,
remove the Lutron wallplate and wallplate adapter from
dimmer. Using pliers, bend side section up and down
until it breaks off. Repeat for each side section to be
removed. Removal of dimmer side sections reduces
maxi-mum load capacity. Refer to chart below for maxi-
mum dimmer capacity.
Dimmer Capacity Chart
Dimmer Rating
No sides removed
600 W
600 W
Technical Assistance
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center. Please provide exact model number when calling.
U.S.A. and Canada (24 hrs/7days)
1.800.523.9466
México
+1.888.235.2910
Other countries 8am – 8pm ET
+1.610.282.3800
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service,
return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TO ONE YEAR
FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM
MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL
DAMAGES. LUTRON'S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION,
DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have
other rights which vary from state to state. Some states do not
allow the exclusion or limitation of incidental or consequential
• Easy-to-follow
damages, or limitation on how long an implied warranty may
last, so the above limitations may not apply to you.
Lutron, Claro, and Skylark are registered trademarks and
Eco-Dim is a trade-mark of Lutron Electronics Co., Inc. NEC is a
• Instrucciones
registered trade-mark of the National Fire Protection Association,
Quincy, Massachusetts. © 2010 Lutron Electronics Co., Inc.
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in U.S.A. 10/10
P/N 030-1352 Rev. A
Lutron Technical Support Center
English
Installation
incandescent or halogen
Normal
Eco-Dim
TM
Switch
Eco
2008,
®
Do Not Remove
Outside Sections
SINGLE-POLE:
Insulated wires connected
Each Control Has Inside
Middle Control Has Two
to two screws of the same
Sections Removed
Side Sections Removed
color. Replace with a SIN-
GLE-POLE dimmer. See
1 side removed
2 sides removed
Step 5a.
500 W
400 W
Important Note: Your wall switch may have two wires attached to the same screw (see
illustrations below for examples). Tape these two wires together before disconnecting.
Connect both wires to the dimmer wire in Step 5.
Fax +1.610.282.1243
http://www.lutron.com
• Easy-to-follow
Instructions
Instructions
• Instrucciones
Fáciles de Seguir
Fáciles de Seguir
030-1352
Turning OFF Power.
1
• Turn power OFF at circuit breaker (or remove fuse).
WARNING: Shock Hazard. May result
in serious injury or death. Turn off
power at circuit breaker before
installing the unit.
2
Removing Wallplate and Switch.
• Remove wallplate and switch mounting screws.
• Carefully remove switch from wall (do not remove wires).
Caution: Verify power
is OFF to switch
before proceeding.
3
Identifying the Type of Circuit.
Different-colored screw (Common).
Actual location may vary.
OR
Ground (Bare
Copper or
Green Wire)
Ground (Bare Copper or
Green Wire)
3-WAY:
Insulated wires connected to three screws. One of
OR
these wires is connected to a screw of a different-
color (not green) or labeled COMMON. MARK or
TAG this wire to identify it when wiring. Replace
with a 3-WAY dimmer. See Step 5b.
4
Disconnecting Switch Wires.
One wire in the
backwired hole
and one to the
screw.
030-1352
1-800-523-9466
24 hrs / 7 days
Wiring the Dimmer.
5
• For installations involving more than one control in a wallbox, refer to the
section on Multigang Installations before beginning.
Note: Wire location will vary by product. Reference wires by color,
not location.
5a - Single-Pole Wiring
Black
Green
Ground
Black
Black
120 V
Green
60 Hz
Ground
Light
5b - 3-Way Wiring
Black
Tag
Tag
Green
Red
Black
Red
120 V
Green
Red
60 Hz
Dimmer
3-Way Switch
Ground
6
Mounting Dimmer to Wallbox.
One continuous
wire to the
• Form wires carefully into the wallbox, mount and align dimmer.
screw.
• Install wallplate.
Start screws.
Screw Terminals:
Turn screws to
loosen.
7
Turning ON Power.
• Turn power ON at circuit breaker (or replace fuse).
Push-in Terminals:
insert screwdriver.
Pull wire out.
Looped Wire: Turn
scrrews to loosen.
www.lutron.com
• Connect the green dimmer ground
wire to the bare copper or green
ground wire in the wallbox. (See
Important Note 4.)
• Connect one of the black dimmer
wires to either of the wires removed
from the switch.
• Connect the remaining black dim-
mer wire to the other wire removed
from the switch.
Note: To use a 3-Way dimmer
(one black and two red wires) in a
single-pole application, cap off one
of the red wires and follow instruc-
tions for single-pole wiring. (If the
on/off switch works backwards,
switch the red wires.)
• NOTE: Only one dimmer can be
used in a 3-WAY circuit.
• Connect the green dimmer ground
wire to the bare copper or green
ground wire in the wallbox. (See
Important Note 4.)
• Connect the black dimmer wire to
the wire removed from the differ-
ent-colored screw on the switch
(marked or tagged wire). Remove
tag from wire.
Ground
• Connect one of the red dimmer
wires to either of the remaining
wires removed from the switch.
• Connect the remaining red dimmer
wire to the remaining wire removed
from the switch.
Light
Align dimmer and