READ AND S AV E TH ES E I N ST R UCT I ON S
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
2. Before servicing or cleaning unit, switch power off
at service panel and lock the service disconnecting
means to prevent power from being switched on
accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring (including
switch location) must be done by a qualified person(s)
in accordance with all applicable codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue(chimney) of fuel
burning equipment to prevent back drafting. Follow
the heating equipment manufacturer's guideline and
safety standards such as those published by the
National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code
authorities.
5. This product may have sharp edges. Be careful to
avoid cuts and abrasions during installation and
cleaning.
6. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. Not for use in kitchens.
9. If this unit is to be installed over a tub or shower, it
must be marked as appropriate for the application
and be connected to a GFCI (Ground Fault Circuit
Interrupter) – protected branch circuit.
10. This unit must be grounded.
11. This unit must be installed into fan housings that are
marked "D-Housing". Other fan housings cannot be
substituted. For use only with NuTone fan models
695, 696N, Nautilus fan models N671, N688 and
Broan fan models 670, 671, 688, 689.
To register this product visit:
www.nutone.com
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. Install fan at least five feet (1.52 m) above floor.
3. To avoid motor bearing damage and noisy, unbalanced
impellers, keep drywall spray, construction dust, etc.
off motor and impeller.
4. Read specifications on product for other information
and requirements.
CLEANING & MAINTENANCE
•
For quiet and efficient operation, long life, and
attractive appearance – lower or remove grille
and vacuum interior of fan with a dusting brush
attachment.
•
The motor is permanently lubricated and never
needs oiling. If the motor bearings make excessive
or unusual noise, replace the motor with the exact
service motor. The impeller should also be replaced.
•
To remove blower assembly - See step 5 on page 3.
OPERATION
Use an on/off switch or speed control to operate this
ventilator.
TOOL REQUIRED
MODEL QKN60
Flat Blade
Screwdriver