How to change the bag

WARNING!
These operations can only be carried out by
trained and qualifi ed personnel who must wear
adequate clothing, in compliance with the laws in
force.
Take care not to raise dust during these
operations. Wear a protective mask.
In case of dangerous and/or toxic dust, you must
use the supplied safety bag for these certifi ed
vacuum cleaners.
The bag must only be disposed of by qualifi ed
personnel and in compliance with the laws in
force.

At the end of a cleaning session

Turn the vacuum cleaner off and disconnect the plug
from the socket.
Wind the connection cable up and hang it in the relevant
compartment (Fig. 13).
Empty the container as described in the "Emptying the
container" paragraph.
Clean the vacuum cleaner as described in the paragraph

"Maintenance, cleaning and decontamination".

Wash the container with clean water if aggressive
substances have been vacuumed.
Store the vacuum cleaner in a dry place, out of reach of
unauthorized persons.
04/2010
Maintenance, cleaning and
decontamination
WARNING!
The precautions described below must be taken
during all maintenance operations, including cleaning
and replacing the primary and HEPA fi lters.
WARNING!
The maintenance, cleaning and decontamination
operations must only be performed with the vacuum
cleaner turned off and the plug disconnected from the
power socket.
It is absolutely forbidden to perform maintenance with
the plug connected to the socket.
Danger of electric shock!
If the user is performing the maintenance operations,
the vacuum cleaner must be disassembled, cleaned
and overhauled as far as reasonably possible without
hazards for the maintenance personnel or other people.
The suitable precautions include decontamination before
disassembling the vacuum cleaner, adequate fi ltered
ventilation of the exhaust air from the room in which it
is disassembled, cleaning the maintenance area and
suitable personal protection.
All parts of the vacuum cleaner must be considered
contaminated when they are removed from the
hazardous zone and appropriate actions must be taken
to prevent the dispersion of dust.
When maintenance or repair procedure are carried out,
all the contaminated elements that cannot be properly
cleaned, must be eliminated.
These elements must be disposed of in sealed bags
conform to applicable regulations and in accordance with
the local laws governing the disposal of such material.
This procedure must also be followed when the fi lters are
eliminated (primary and HEPA fi lters).
Compartments that are not dust-tight must be opened
with suitable tools (screwdrivers, wrenches, etc.) and
thoroughly cleaned.
WARNING!
This vacuum cleaner can be equipped with a
HEPA fi lter for vacuuming dust hazardous to one's
health. The procedures for servicing and emptying
the vacuum cleaner including removing the dust
container, must only be performed by specialised
personnel wearing protective clothing. Do not use
without the complete fi lter system in place.