INFRARED RECEIVER
6. Connection
o Thread the connection cable of the panel through the hole in the base.
o Please refer to the installer manual for the wiring connections.
o Remount the panel on the base.
1 Infrared receiver
2 Indoor unit PCB
3 Connection wire (max length 1,8m)
COMP
TIMER
OPER
7. Alarms
•
The faults of the indoor unit are indicated by the flashing of the light OPER.
•
The number of flashes indicates the fault code.
•
TIMER indicator light should not be flashing.
•
The faults of the outdoor unit are indicated by flashing lights TIMER and OPER.
•
The number of flashes of TIMER indicates the tens, OPER indicator light flashes indicates the units, to get
the error code, subtract 20 to the figure obtained.
•
The description of the anomaly is indicated in the user or installation manual.
1
3
3
2