Technical Data - Festo Variable Transformer EduTrainer Instrucciones De Utilizacion

Transformador de regulación
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7 Technical Data

Technical data
Input voltage, L1/L2/L3
Input frequency
Maximum current, L1/L2/L3 connection
Rectifier input voltage (T1/T2)
Rectifier output voltage T1
Rectifier output voltage T2
Maximum current of CD outputs
Potentiometer fuse
Protection class
Overvoltage category
Degree of contamination
Electrical connections
Operating temperature range
Max. relative humidity
Degree of protection
Device operation
Dimensions
(H x W x D in mm)
Weight
Certifications
CE marking per
© Festo Didactic 8037346
3 x 400 V AC ±10%
50 to 60 Hz
16 A, must be protected by back-up fuse
Max. 230 V AC
Approx. 10 to 230 V DC rms
210 V DC rms
4 A, not protected
Resettable 4 A fuse
1, operation with protective grounding
II, operation in building installations
2, laboratory environment
Safety laboratory cables per EN 61010-031, min. conductor cross-section 1 mm²
5 to 40° C / 100%
80 %
IP 20 (not attached to the mounting frame)
Use only indoors, max. altitude: 2000 m above sea level
297 x 266 x 140
4 kg
The Low Voltage Directive
RoHS directive
Variable Transformer EduTrainer - Operating instructions