Blue Tube Connection- Angle Stop Valve
!
CAUTION
Water supply line to the system must be from the cold water supply
line only. Hot water will severely damage your system.
Step 1
- Turn off the cold
water supply to the
faucet by turning
the angle stop valve
completely off.
Step 2
- Open cold water
sink faucet to relieve
pressure.
Step 3
- Place a small
container under the
cold water angle stop valve to catch any runoff water.
Disconnect the cold water faucet supply hose from
the cold water angle stop valve.
Step 4
- Locate the blue
3/8" tube in the
parts bag. Remove
a brass nut, plastic
delrin sleeve and
brass insert from
the parts bag. To
assemble, place the
brass nut on the
blue tube first (Open end out), then the sleeve and
then push the brass insert all the way into the end of
the tube. (See Picture).
Step 5
- Secure the blue tube to the cold water stop valve
using the brass nut. Tighten using an adjustable
wrench.
Blue Tube Connection- Faucet Hose
Step 1
- Locate the threaded
3/8" male stem
adapter fitting in the
parts bag. Thread
the stem adapter on
to the supply hose
attached to the
faucet and tighten
with an adjustable
wrench.
Step 2
- Locate the 3/8"x 3/8" Quick Connect union in the
parts bag. Push the union on to the 3/8" stem
adapter fitting attached to the faucet hose until fully
seated.
Step 3
- Connect the open end of the 3/8" blue tube to the
open end of the 3/8"x 3/8" Quick connect union
fitting by pushing the tube into the adapter until
fully seated.
System Module Mounting
Step 1
- Mount the system to
one side of the cabinet
allowing 3" of clearance
below the filter for
easy filter removal and
replacement. Mark the
location for the mounting
screws on the cabinet
wall under the sink. In the
parts bag, locate the two self tapping screws. Using
an electric drill with a Phillips bit, screw them into the
cabinet at the marked location. Hang the system on
the screws using the mounting holes in the bracket.
Blue Tube Connection - Filtration System
Step 1
- The tubing is now
connected on one end
to the faucet supply, and
the other end to the shut
off valve forming a loop.
This loop of tubing needs
to be cut at a point that
provides enough length
on both sides to connect
to the filtration unit. This
location varies depending
on where the filtration unit is mounted relative to the
shut off valve and faucet connection. Cut the blue
hose at this point, ensuring the ends are square and
not angled.
Step 2
- Connect the 3/8" blue tube coming from the angle
stop valve into the left side of the filtration system (IN),
by pushing the tubing firmly into the quick connect
fitting. Connect the 3/8" blue tube coming from the
3/8" adapter
faucet supply hose into the right side of the filtration
system (OUT), by pushing the tubing firmly into the
3/8" quick
quick connect fitting.
connect union
Other end of
blue tubing
Page 4