Perfomance Data Sheet
Pure H2O
In U.S.-Watts Regulator Co.,
N. Andover, MA 01845 (Watts.com);
In Canada-Watts Water Technologies (Canada),
Inc., Toronto, ON M5J3G6 (Watts.ca)
High Capacity Quick Turn Carbon Block
Filtration System- H2O-DWCB100
GENERAL USE CONDITIONS
WARNING
!
1: System to be used with municipal or well water sources treated and tested on regular basis
to insure bacteriological safe quality. DO NOT use with water that is micro biologically unsafe or
of unknown quality without adequate disinfection before or after the system. While testing was
performed under standard laboratory conditions, actual performance may vary. Systems certified
for cyst reduction may be used on disinfected waters that may contain filterable cysts.
2: Operating Temperature: Maximum 100
3: Operating Water Pressure: Maximum 125-psi (861.85kpa)
4: Maximum Flow Rate: 1.5 gpm (5.69 lpm)
5: Rated Capacity Chlorine: 10,000 gallons (37,854 liters)
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVAL:
Depending on incoming feed water conditions replacement time frame may vary.
Description
High Capacity Quick Turn Carbon Filter
The H2O-DWCB100 system has been tested according to NSF/ANSI 42, 53, for reduction of the substances
listed below. The concentration of the indicated substances in water entering the system was reduced to a
concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI
42 and 53. This system is certified to NSF/ANSI standard 372 for 'lead free' compliance.
Testing parameters:
Cyst Reduction
Influent Avg.
370000
Effluent Avg.
<25
Percent Reduction
>99.98%
Maximum Effluent
<25
This system is assembled at Watts Facility-
Avenida Obregon 4055 Parque Industrial El Cid, Nogales, 84092 Mexico
F (38
C)
o
o
Model / Part Number
H2O-F45 / 88005232
Flow rate 1.5 gpm
Flow Reduction
count/L
Eighth Cycle
count/L
25%
50%
count/L
75%
Minimum 40
F (4.4
C)
o
o
Minimum 10-psi (69kpa)
pH 7.6 gpm
Water pressure: 60 psi.
Influent
130000
210000
333000
810000
Page 6
Change time Frame
12 Months or 10K Gallons
Effluent 1
Effluent 2
<25
<25
<25
<25
<25
<25
<25
<25