7 Technical data

7.1 General specifications

Parameters
Operating pressure
Operating voltage
Digital inputs/outputs
Inputs:
Outputs:
Analog inputs/outputs
Inputs:
Outputs:
Electrical connection
Pneumatic connection
Compressed air consumption at 600 kPa (continuous cycle)
Dimensions
Subject to change
20
9 (10)
10
1 (0)
0
Value
600 kPa (6 bar)
24 V DC, 4 A, ≤ 100 W output power, SELV/PELV limited
power supply (LPS)
Max. 24 V DC
Max. 2 A per output
Max. 4 A total
0 ... 10 V DC
or ± 10 V DC
24-pin IEEE-488 socket (SysLink)
SUB-D 15-pin socket
RJ 45 socket
Plastic tubing with 6 mm outside diameter
3 l/min
350 x 700 x 450 mm