7 Technical data
Technical data, Operator and Signalling Unit EduTrainer
Input voltage
Output voltage
Electrical connections
Protection class
Overvoltage category
Degree of contamination
Electrical connections
Protective grounding terminal
Operating temperature range
Protection
Dimensions (H x W x D)
Weight
Subject to change
Certifications
CE marking
8 Description
The Operator and Signalling Unit EduTrainer
can be used with the "Fundamentals of circuits with contacts" training package in order to control
contactors and relays, and to indicate signal statuses.
Caution!
The device may only be used on power supplies with safety extra-low voltage (24 V).
Maximum backup fuse 4 A
© Festo Didactic 8049695
®
24 V DC / 4.5 A
24 V DC / 4.5 A
4 mm safety sockets
1, operation with protective earthing
II, operation in building installations
2, laboratory environment
Safety laboratory cables per EN 61010-031, min. conductor cross-section: 1 sq. mm
PE+ contact
5 ... 40° C
IP 20
267 mm x 297 mm x 95 mm
Approx. 3 kg
Low-voltage directive
RoHS directive
®
includes pushbuttons, control switches and indicators which
Operator and Signalling Unit EduTrainer
®
25