Ÿ
The installation must conform to local codes, or
in the absence of local codes, with the standard
for the storage and handling of liquid petroleum
gases.
Ÿ
A dented, rusted or damaged tank may be
hazardous and should be checked by your tank
supplier. Never use a tank with a damaged
valve connection.
Ÿ
The tank must be arranged to provide for vapor
withdrawal from the operating cylinder.
Ÿ
Never connect an unregulated tank to the
heater.

LEAKAGE TEST

Gas connections on the heater are leak tested at
the factory prior to shipment. A complete gas
tightnes scheck must be performed at the
installation site due to possible mishandling in
shipment or excessive pressure being applied to
the heater.
Make a soap solution of one part liquid
Ÿ
detergent and one part water. The soap
solution can be applied with a spray bottle,
brush or rag. Soap bubbles will appear in case
of a leak.
The heater must be checked with a full cylinder.
Ÿ
Make sure the safety control valve is in the OFF
Ÿ
position.
Turn the gas supply ON.
Ÿ
In case of a leak, turn off the gas supply. Tighten
Ÿ
any leaking fittings, then turn the gas supply on
and recheck.
Never leak test while smoking.
Ÿ
OPERATION AND STORAGE
1.Turn on the valve on the gas supply cylinder
completely.
2. Press and turn the variable control knob to
PILOT position (counter-clockwise 90 º)
3. Press down the variable control knob and hold
for 60 seconds. While holding down the variable
control knob, press the igniter button several
times until the pilot flame lights. Release the
variable control knob after the pilot flame lights.
Note:
- If a new tank has just been connected, please
allow at least one minute for the air in the gas
pipeline to purge out through the pilot hole.
- When lighting the pilot flame make sure that the
variable control knob is consinuously pressed
down while pressing the igniter button. Variable
control knob can be released after the pilot flame
lights.
- If the pilot flame does not light or it goes out,
repeat step 3.
4. After the pilot flame lights, turn the variable
control knob to maximum position and leave and
leave it there for 5 minutes or more before turning
the knob to desired temperature position.
TO TURN OFF THE HEATER
1. Turn the variable control knob to PILOT position.
2. Press and turn the variable control knob to OFF
position.
3. Turn off the valve on the gas supply cylinder
completely.
Storage:
1. Always close the gas valve of the gas cylinder
after use or in case of a disturbance.
2. Remove the pressure regulator and the hose.
3. Check the tightness of the gas valve and for
damage. If you suspect a damage, have it
changed by your gas dealer.
4. Never store liquid gas cylinder in a sub-terrain, or
at places without adequate ventilation.
12
ENG

Publicidad

Tabla de contenido
loading

Tabla de contenido