NEW MODEL 2011
DESCRIPTION
Monitor for video door entry system with 4 and 8 digit coding and decoding.
Provided with fixing bracket with terminal block, 3 push-buttons (lock release
and 2 adidtional functions), 3 level call volume adjustment and exclusion of
call signalled by red led. The green LED is used for an additional signaalling
(when properly connected).
This monitor is used in conjuction with power supply type 6948.
204 mm
Monitor technical specifications
- Wall-mounted monitor in ABS
- Backing plate and plugs for wall-mounted fixture or 3-module box.
- TFT LCD 3,5" for 6344 and 6354.
- Electronic circuit on interchangeable cards.
- Standard video signal CCIR 625 lines 50 squares for 6344 (b/w) and PAL for
6354 (color).
- Video pass band 4 MHz
- Operating temperature from 0° to +40° C.
- Electronic ringtone.
- Input for door calls with different ringtone from panel calls.
- Output for additional ringtone.
PROGRAMMING AND OPERATION
To program the monitor number press (by inserting a small screwdriver
through the hole Fig. 1, detail A) the push-button
side of monitor and then press and keep pressed the push-button. If the ope-
ration has been carried out correctly, the set enter the programming mode by
lighting the diode LED (Fig. 1, detail B) also visible through the hole under the
monitor. Now the push-button
light up repeat the operation. Lifting the monitor handset it is possible to
communicate with the secondary entrance panel in order to send the code
related to the monitor to be programmed. When the code coming from the
entrance panel arrives to the monitor, this stores it and keeps it in memory
until the next programming, even during a mains failure. The monitor will swi-
tch the led off confirming the programming. During the programming phase
the lock release command is not active. In case of installations with stairs with
more than one entry, for the only programming phase , it is necessary to re-
move the connector related to the monitor riser of entrance panels, leaving
only one in function. The programming operation may be repeated several
times by using numbers included between 00000001 and 99999999.
PROCEDURE FOR "TOUCH KEY" PROGRAMMING
To program a "touch key" in the monitor memory follow the underwritten pro-
cedure:
1) Call the monitor from a digital keypad entrance panel
2) Re-dial the number and press the intercommunicating call push-button
from the entrance panel
3) Select the position in the memory, by using the "FRECCIA SU" (arrow up)
and "FRECCIA GIU'" (arrow down), where you want to memorize the key
and press C.
4) Lean the key "TOUCH" in the proper entrance panel slot; you will hear an
acoustic signal on the monitor handset.
5) From now you will have 5 seconds to memorize the key by pressing the
monitor "lock" push-button; once the programming has been carried out
you will hear three beeps and the monitor will switch off. If the program-
ming time expires before you press the lock push-button, the interphone
will switch off without programming the key and all the procedure must be
repeated from the beginning.
EN
74 mm
present on the lower
can be released. If the diode does not
.
ADJUSTMENT OF CALL/UNATTENDED CALL FUNCTION
The 4 position selector (Fig. 1, detail C) allows the loudspeaker volume to
be ajusted and, if set to the last left position, it excludes the audio by lighting
the red LED. If a call is made during this period, the monitor does not sound
and it is not activated, but it signals the call making the led flash and a call
be routed to the switchboard. The number of flashings (max 4) indicates the
number of incoming calls. Setting the selector again, the normal operation is
re-establised and the number of incoming calls stored in the memory on this
mode is cancelled.
VIDEO SIGNAL CONNECTION
If the video signal is connected by a coaxial cable, the deviator (Fig. 2, detail
A) (placed on the monitor rear side) must be set to the left hand position for
the coxial cable version, or in the right hand position for version withoutcoaxial
cable.
N.B. The jumper present on the monitor rear side allows the VIDEOMO-
VING function to be carried out on preset entrance panels or Function 2;
on the contrary with cut jumper it allows the selfactivation function to
be carried out (Fig. 2, detail B), see entrance panel programming.
TERMINAL BLOCK
1)
Digital call line
2)
Secondary entrance panel audio line
3)
Audio line
4)
Negative line
5)
+ 13,5V DC line
6)
Inserted monitor signalling (for additional chimes or other services)
7)
Monitor negative line
8)
Monitor positive line
9)
Line for outside door call.
10) Supply voltage for video floor distributor
11) F2 - connection for auxiliary functions, to be connected if indicated on the
diagram.
12) F1 - Connection for auxiliary functions, to be connected if indicated on
the diagram.
13) Supply voltage for green LED indicator
Lower side of monitor
Fig. 1
Rear monitor
MONITOR
COLL.
PAL / NTSC
6354
COLORE - COLOR
6324/C
6344
B/N
- B/W
6324
DC 18V INT 6W 335mA
MATRICOLA
REG.
N. MVAP
Fig. 2
CON PONTICELLO INSERITO = FUNZIONE F2
PONTICELLO TAGLIATO = FUNZIONE AUTOACCENSIONE
WITH JUMPER INSERTED = FUNCTION F2
WITH JUMPER CUT = SELFACTIVATION FUNCTION