E-100-L-E
ENGLISH
Sira 14ATEX3015X
II 2 G Ex eb mb IIC T* Gb
II 2 D Ex tb IIIC T***°C Db
IP66
Ta = –40°C to +40°C
IECEx SIR14.0007X
Rated Voltage: 277V
(BTV, QTVR, XTV, KTV)
110V (VPL1), 254V (VPL2)
RU C-BE.МЮ62.B.00054/18
Ex e mb IIC Gb U Ex tb mb IIIC Db U
Ta –55°C...+40°C IP66
* The temperature class/maximum surface temperature is directly related to the associated process temperature and trace heating cable with which it is assembled, refer
to Conditions of Manufacture for the appropriate equipment marking.
For system Temperature Code, see heating cable or design documentation.
:
Maximum pipe temperature
Heater type
BTV
QTVR
XTV
KTV
VPL
Cable
110V
5VPL1-CT
235°C
10VPL1-CT
215°C
15VPL1-CT
190°C
20VPL1-CT
150°C
Ambient Temperature: ATEX/IECEX: –40°C to +40°C; EAC: –55°C to +40°C
Installation instructions for nVent RAYCHEM E-100-L-E end seal kit. For use with all nVent RAYCHEM BTV-, QTVR-, XTV-,KTV- and
VPL-heat ing cables.
Specific Conditions of Use
1. Some external parts of the system are non-conducting and may generate an ignition-capable level of electrostatic charges under
certain extreme conditions. The user should ensure that the equipment is not installed in a location where it may be subjected
to external conditions (such as high-pressure steam) which might cause a build-up of electrostatic charges on non-conducting
surfaces. Additionally, cleaning of the equipment should be done with a damp cloth.
2. The maximum process temperature of the Lighted End Seals is limited to 150°C; this may be further limited by the type of heat-
ing cable that is being used, therefore. When fitting the Lighted End Seals, the user/installer shall take into account any restric-
tions that are applicable to the cable.
3. The supply circuit shall be protected by a fuse capable of withstanding a prospective short current of 1500A.
4. The Lighted End Seals must be pipe mounted in a single orientation, with the gland entry adjacent to the process pipe, as per the
manufacturer's installation instructions
Warning: To prevent electrical shock, short circuit or arcing, this prod uct must be in stalled correctly and water ingress must be
avoided before and during the in stal la tion.
Avoid skin and eye contact with sealing grease. Consult Material safety data sheet VEN 0058 (INSTALL027).
Before installing this product, read the installation instructions completely.
Zone 1 AEx eb mb IIC T* Gb
Zone 21 AEx tb IIIC T*°C
(1) Except VPL
Ex eb mb IIC T* Gb
®
Ex tb IIIC T*°C Db
IP66
Rated voltage: 277 Vac
Ex e mb IIC T* Gb
IEx
Ex tb IIIC T* °C Db IP66
IEx 15.0089X
Tmax continuous
65°C
110°C
121°C
150°C
See tables below
Cable
5VPL2-CT
10VPL2-CT
15VPL2-CT
20VPL2-CT
(1)
Hazardous Locations:
®
Tmax intermittent
1000h cumulative
85°C
110°C
250°C
250°C
230V
230°C
210°C
180°C
150°C
Class I, Div. 2, Groups A,B,C,D
Class II, Div. 1 and 2, Groups E, F, G
Class III
Type 4X
Tmax power off
250°C
254V
225°C
200°C
145°C
Not allowed
nVent.com/RAYCHEM | 3