This product must be grounded. If it should malfunc-
tion or breakdown, grounding provides a path of least
resistance for electric current to reduce the risk of
electrical shock. This product is equipped with a cord
having an equipment-grounding conductor and ground-
ing plug. The plug must be inserted into an appropri-
ate oulet that is properly installed and grounded in
accordance with all local codes and ordinances.
GROUNDED
OUTLET BOX
This product is for use on a nominal 120 volt circuit and
has a grounding attachment plug that looks like the
plug illustrated in Fig. 5. Make sure that the product
is connected to an outlet having the same configura-
tion as the plug. No adaptor should be used with this
product.
Tampa del
toma corriente
con polo de
tierra
Boîte de
sortie mise
à la terre
Use only an approved extension cord with three
conductors, a plug with three terminals, and a
connector body with three holes. The machine has
a power cord with wire size 14 AWG (AWG means
American Wire Gauge).
CLARKE TECHNOLOGY Operator's Manual FM-1500HD, 1700HD, 2000, & 2300
120 VOLT MACHINES
Instructions for connection to the power
supply and the electrical ground.
WARNING: Improper connection of the
equipment-grounding conductor can
result in a risk of electric shock. Check
with a qualified electrician or service
person if you are in doubt as to whether
the outlet is properly grounded. Do not
modify the plug provided with the
product - if it will not fit the outlet, have a
proper outlet installed by a qualified
electrician.
WARNING: To prevent possible electric
shock, protect the machine from rain.
Keep the machine in a dry building.
WARNING: To prevent possible electric
shock, always use a 3-wire electrical
system connected to the electrical ground.
For maximum protection against
electrical shock, use a circuit that is
protected by a ground fault circuit
interrupter. Consult your electrical
contractor.
WARNING: Do not cut, remove or break
the ground pin. If the outlet does not fit
the plug, consult your electrical
contractor.
WARNING: Have worn, cut or damaged
cords replaced by an authorized service
person.
EXTENSION CORDS
WARNING: If you use an extension
cord, use an extension cord with
minimum wire size 12 AWG. Do not use
an extension cord longer than 50 feet.
Do not join two extension cords.