GENERAL SETUP & OPERATION, PNEUMATIC AMBIENT AIR PUMP
MODEL BAC-20P
STEP 1)
Install rubber feet on to the pump(s) as shown. Note: The rubber feet are
packaged separately for shipment.
STEP 2)
Check intake filter for excessive dirt and change if necessary. Set compressor
in a clean environment away from hazardous dusts, mists, vapors and fumes.
STEP 3)
Make sure oil level in the lubricator is to the full level recommended; add oil if
necessary. Factory recommended oil is SAE #10 automotive engine oil. Note:
The oil level in the bowl should be 1/2 - 3/4 full.
STEP 4)
Use only constant flow Type-C respirators. Attach hose(s) and mask(s) to
system before turning the unit on, failure to do so will cause internal motor
damage.
STEP 5)
Secure a primary air source. Maximum requirement 75 cfm at 80psi. Attach a
minimum 1/2" I.D. hose to the inlet fitting.