D) Configuration of the output modes – Installer programming
Locations
Code duration
E) Personal safety – Installer programming
Locations
No. of false entry
F) Door forced-open alarm – Installer programming
Locations Code of functions
G) Output activation announcer – Installer programming
Locations Code of functions
HAA9523S
0 to 9
4 to 8 digits
0 to 9
4 to 8 digits
Validation
1 to 999s
1 to 999s
1 to 999s
Validation
5 to 10
00
Validation
Validation
10 user codes in group 2 for output 2
10 user codes in group 3 for output 3
Comments
Output 1 momentary mode from 1 to 999 seconds
Output 1 in start/stop mode (toggle)
Output 1 in start/stop mode w/ accelerated code
Output 2 momentary mode from 1 to 999 seconds
Output 2 in start/stop mode (toggle)
Output 2 in start/stop mode w/ accelerated code
Output 3 momentary mode from 1 to 999 seconds
Output 3 in start/stop mode (toggle)
Output 3 in start/stop mode w/ accelerated code
Comments
After 10 successive false codes, the keypad locks
during 30 seconds
After 10 successive false codes, the duress output
switches to ground
Selectable after 5 to 10 successive false codes, the
keypad locks during 15 minutes. The keypad can be
reset to release locking with the master code at any
time during the locking period.
All of the above securities disappear
Comments
Door forced-open alarm is enabled
Door forced-open alarm is disabled
Comments
1-second notifying beep is given to notify the person
outside to open the door when the output relay is
activated with a user code or egress button. Good for a
locking device without sound such as a magnetic lock.
Notifying beep disabled and replaced by 2 short
successful code entry beeps for valid user codes
7