10 – Specifications
Input
Voltage Range
Frequency Range
Power Factor
Output
Voltage Range
Voltage Adjustment
Voltage Regulation
Capacity
Rated Power Factor
Wave Form
Frequency Stability
Frequency Regulation
Transfer Time to Battery
Crest Factor
Efficiency (AC to AC, Normal Mode)
Efficiency (AC to AC, Economy Mode)
Estimated Full Load Runtime
Estimated Half Load Runtime
Physical
Dimensions (H x W x D)
Input/Output Connection
Unit Weight
11 – Storage and Service
Storage
First turn the UPS system's output and utility input breaker OFF, then disconnect the UPS system's input from the AC utility power source.
Next, disconnect all equipment. The UPS system must be stored in a clean, secure environment with a temperature less than 40° C and a
relative humidity less than 90% (non-condensing). Note: If the UPS system remains off for an extended period of time, it should be turned
on periodically to allow the batteries to recharge. The UPS system should be turned on and the batteries should be recharged at least one
uninterrupted 12-hour period every three months in moderate-temperature environments (-15° to 30° C), or every two months in high-
temperature environments (30° to 40° C). Failure to recharge the batteries periodically may cause irreversible battery damage.
Service
The UPS system is covered by the limited warranty described in this manual. Extended and on-site warranty options are also available. For more
information, call Tripp Lite Customer Service at +1.773.869.1234. If returning the UPS system to Tripp Lite, carefully pack the UPS system using
the original packing material that came with the unit. Enclose a letter describing the symptoms of the problem. If the UPS system is within the
warranty period, enclose a copy of the sales receipt.
Up to 160-280/277-485V AC (3Ø, 4-Wire + Ground, Wye)
(160-176/277-305V AC at Load < 75%)
45 to 65 Hz
Up to 0.99 at 100% Linear Load
User-Selectable 200/220/230/240V AC (1Ø, 2-Wire + Ground)
±0%; ±1%; ±2%; ±3%
±2%
10 kVA / 7 kW
0.8 Lagging
Pure Sine Wave, THD <3%
±0.2% (Free-Running)
±1%; ±3%
0 ms
3:1 Acceptable
Up to 91%
Up to 93%
5 minutes
14 minutes
135 x 440 x 680 mm (Power Module)
Hardwire
28 kg (Power Module)
18