Nozzle Location - Siemens SITRANS LR560 Guia De Inicio Rapido

Ocultar thumbs Ver también para SITRANS LR560:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 103
Installation
WARNINGS:
• Installation shall be performed only by qualified personnel and in accor-
dance with local governing regulations.
• Never attempt to loosen, remove, or disassemble process connection or
instrument housing while vessel contents are under pressure.
• The user is responsible for the selection of bolting and gasket materials
which will fall within the limits of the flange and its intended use and which
are suitable for the service conditions.
• Improper installation may result in loss of process pressure.
Notes:
• For European Union and member countries, installation must be according to ETSI EN
302372.
• SITRANS LR560 units are pressure tested, meeting or exceeding the requirements of the
ASME Boiler and Pressure Vessel Code and the European Pressure Equipment Directive.

Nozzle location

Beam angle
• Beam angle is the width of the cone
where the energy density is half of the
peak energy density.
• The peak energy density is directly in front
of and in line with the antenna.
• There is a signal transmitted outside the
beam angle, therefore false targets may
be detected.
Emission cone
• Keep emission cone free of interference
from ladders, pipes, I-beams or filling
streams.
• Avoid central locations on tall, narrow ves-
sels.
Environment
• Provide easy access for viewing the dis-
play and programming via the hand pro-
grammer.
• Provide an environment suitable to the
housing rating and materials of construc-
tion.
7ML19985XR81
SITRANS LR560 (FF) – QUICK START MANUAL
min. 1 m (39")
emission
cone
Page EN-5

Publicidad

Tabla de contenido
loading

Tabla de contenido