3.4 Light distribution curve

3.5 Environment

The LED fixture is intended to be used in climate-controlled grow rooms and indoor farms. The product may be
used in damp environments but may not be used in wet environments or outdoors.
The product will operate in ambient temperatures from -10ºC to 40ºC but will function at optimal level
between 20ºC to 30ºC.
The product will operate in 20% – 90% humidity, non-condensing.

3.6 Legal

This product is CE certified compliant with LVD and EMC directive test standards.

4. SAFETY RECOMMENDATIONS AND WARNINGS

Warning! Carefully read the warnings below before using or working with the product!
• Always adhere to the local rules and regulations when installing or using the LED fixture.
• Do not open or disassemble the LED fixture as it contains no serviceable parts inside. Opening or modifying
the LED fixture can be dangerous and will void the warranty.
• Do not use the LED fixture when either the LED fixture or its power cable are damaged. Replace the power
cable with correctly rated cable only.
• Modifications to the cables can lead to unwanted electromagnetic effects which may make the product
not comply with legal requirements.
• Do not expose the LED fixture to:
Condensing humidity, heavy mist or direct spray;
Ambient temperatures outside the specified range;
Dust and contamination;
Direct sunlight during use or HID light that may heat up the driver.
• Always disconnect the LED fixture from mains before performing any maintenance.
• Always allow for a cool down period of at least 20-30 minutes before touching the LED light bars.
Touching the LED bars when the fixture is lit or immediately after may result in burns!
• Natural convection removes heat away from the heatsink. In order for the system too properly cool itself,
allow at least 5cm of space is required between the fixture and the roof of your grow area.
• Do not use abrasive materials or aggressive cleaning agents to clean the LED fixture as this may damage
the secondary optics. Instead use a clean dry fabric/cloth.
• Do not use the LED fixture near flammable, explosive or reactive substances. The LED fixture can reach
temperatures of 40ºC.
• Do not use sulphur vaporizers or water misters.
• The installation and use of the LED fixture is the responsibility of the end user. Incorrect use or installation can
lead to failure and damage to the LED fixture. Damage to the LED fixture and electronic circuitry as a result
of incorrect installation and use revokes the warranty.
Unit: cd
C0/180 , 117.9
C30/210 , 118.0
C60/240 , 118.0
C90/270 , 117.9
Average Beam Angle
(50%) : 117.9 DEG