5.2
Connect the hydraulic hoses
5.2.1
General
WARNING
Never use damaged couplers.
Caution
Never use pliers or similar to connect the hydraulic couplers.
5.2.2
Connect the High-Flow couplers
See Fig. 9.
WARNING
Always make sure that the pressure relief valve is in the open (0) position, before you
connect hydraulic hose(s) to the pump.
Remove the dust caps from the female and male couplers.
Check the couplers for dirt and damage and clean them if necessary.
Screw the male coupler into the female coupler and tighten the locking ring as far as possible.
Screw the dust caps together, to prevent from contamination.
5.2.3
Connect the Quick-Lock couplers
See Fig. 10.
WARNING
Always make sure that the pressure relief valve is in the open (0) position, before you
connect hydraulic hose(s) to the pump.
Turn the retainer ring on the female coupler anti-clockwise to unsecure the lock ring.
Remove the dust cap from the female coupler by pushing back the lock ring. The dust cap slips off.
Pull the dust cap from the male coupler.
Check the couplers for dirt and damage and clean them if necessary.
Push the lock ring on the female coupler backwards.
Push the couplers into each other and the lock ring of the female coupler will automatically lock.
Check whether the couplers can not be pulled apart with a normal manual effort and turn the
retainer ring clockwise so that the lock ring is secured.
Connect the dust caps together.
5.3

Disconnect the hydraulic hoses

5.3.1
General
Caution
Never use pliers or similar tools to disconnect the hydraulic couplers.