Operating instructions
5. Maintenance.
5.1 - The cables should be checked regularly
for wear (ie: kinks, fraying, single strand
breakage, etc). Worn cables must be replaced
immediately. Do not use the lift with worn
cables.
Only use handle cables DIN 3060.
5.2 - The lift has been lubricated in the factory.
It is nevertheless recommended that you
lubricate the gear drive, the bearing bushes on
the drive shaft and drum hub, the handle
threads and the tower sections.
ATTENTION:
Do not apply oil or grease to the brake
mechanism.
The brake washers have been greased
with a special heat and pressure resistant
grease. Do not use other greases as this will
affect the winch brake performance.
It is not necessary greasing the brake
washers.
5.3 - The TE-074P lift must be inspected by
trained personnel at least once annually.
5.4 - In order to maintain the original parts of
the manufacturer's design must be used.
The user forfeits all warranty rights to
claim if parts other than those of the
manufacturer are used or the product is
modified in any other way.
5.5 - When spare parts are required, you must
quote the reference number as included in this
booklet.
Depósito legal y Copyright 2006. Todos los derechos reservados.
All manuals and user guides at all-guides.com
ENGLISH
6. Guarantee.
If the during the guarantee period because of
poor workmanship or faulty materials VMB
Española, S.A. will repair or replace it.
The guarantee period for Europe is at 2
years.
The guarantee does not cover damage
caused by improper use, wear and tear
unauthorised repairs. The guarantee does not
cover consumables or defects that have only
a negligible effect on the value or operation of
the elevator tower.
7. Certifications
-
EC Machinery Directive
89/392/ECC and 98/37/ECC
- BGV C1 (GUV-VC1) / BGG 912 (GUV-G912)