LEAD-ACID
CHARGING PROGRAMS
Settings are made by pressing the MODE-button. After about two seconds the charger activates the selected program. The
selected program will be restarted next time the charger is connected.
The table explains the different Charging Programs:
Program
Normal battery program 14.4V/25A. Only for lead-acid batteries.
NORMAL
Recond program 15.8V/1.5A
Use Recond to return energy to empty WET and Ca/Ca batteries. Recond your battery once per year and after
RECOND
deep dischare to maximize lifetime and capacity. The Recond program adds the Recond step to the normal
battery program. Only for lead-acid batteries.
Supply program 13.6V/25A
Use as a 12V power supply or use for float maintenance charging when 100% capacity of the battery is
SUPPLY
required. The Supply program activates the Float step without time or voltage limitation. The spark protection
on the battery charger is disabled during the SUPPLY program.
8 • EN
Explanation