CAUTIONS AND WARNINGS
CE REQUIREMENT: Use Pre-formed loops with built-in surge suppression for CE
compliance. Connect shield on lead in wire to earth ground.
CE REQUIREMENT: Use CE rated power supply for CE compliance providing
suppression as specified by EN61000-4-5.
Not to be used in personal safety applications.
When more than one loop detector is used, set each one to a different frequency.
Refer to DIP switch diagram for frequency settings.
IMPORTANT:
This product is an accessory or part of a system. Always read and follow the manufacturer's
instructions for the equipment before connecting this product. Comply with all applicable codes and
safety regulations. Failure to do so may result in damage, injury or death.
Sensibilità
Display
Frequenza della spira
Induttanza della spira
Regolazione automatica
Adattamento ambientale
Protezione sovratensione
Relé
Capacità del contatto
Indicatore alimentazione /errore della spira
Rilevamento /indicatore di frequenza
ASB (Automatic Sensitivity Boost)
Alimentazione
Consumo (Stand-by /rilevamento)
Temperatura di funzionamento
Dimensioni (L x l x h)
Modo di fissaggio
Peso
Connettore
A1H-U
6-1621238 rev.0 09/12/2013
All manuals and user guides at all-guides.com
Specifiche tecniche
10 livelli da 0 a 9
Indica la sensibilità da 0 a 9
Aiuto diagnostica
4 frequenze (bassa, medio - bassa, medio - alta, alta)
20...2000µH (Fattore Q > 5)
Il rilevatore si accorda alla spira al momento
dell'alimentazione e dopo la misura della frequenza .
Compensazione automatica
Sistema protetto da delle protezioni anti-sovratensione
incorporate
1 relè (N.A./COM/N.C.)
1A @ 24VDC...120VAC
Led verde
Led rosso
Aumenta automaticamente la sensibilità dopo il
rilevamento iniziale per evitarne la perdita in caso di
veicolo alto.
12VDC...24VDC, 24VAC
15mA/45mA
-40˚C...82˚C
0...95% d'umidità relativa
74mm x 23mm x 84mm
Guida DIN 35mm
113 g
A vite