Troubleshooting

Problem
Motor not running.
Motor stops immediately after
starting.
Motor runs, but no suction.
Motor runs, but poor suction.
Machine blows dust.
Abnormal sound from
machine.

EC Declaration of Conformity

We hereby declare that DC 5900 is in conformity with the following Directives and Standards: 2006/42/EC, 2014/35/EU,
2014/30/EU, EN 60204-1:2006/A1:2009, EN1822-1:A1:2009.
Dustcontrol AB
Anna-Lena Berg / CEO
2019-01-08
22
All manuals and user guides at all-guides.com
Cause
Power supply not connected.
Incorrect fuse.
Suction hose not connected. Hose blocked.
Suction hose perforated.
Blocked filter.
Suction hose too long or narrow.
Hose partially blocked.
Top of machine poorly fitted.
Dust trapped in cyclone.
The pump is rotating in the wrong direction.
Filter loose or damaged.
Peter Söderling / Technical Manager
DC 5900, Art.nr. 42838-I
Action
Connect power supply.
Replace with correct fuse.
Connect hose. Reverse or clean hose.
Replace hose.
Clean or replace.
Replace hose.
Reverse or clean hose.
Adjust fitting.
Remove top and clean cyclone.
Let an electrician change the phase.
Check and replace as necessary.
Book service.