This equipment has been tested and found to
FCC compliance
comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection
against harmful interference when the equipment is
operated in a commercial environment. This
equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instruction manual, may cause
harmful interference to radio communications.
You are cautioned that any changes or modifications
not expressly approved by the party responsible for
compliance could void the user's authority to operate
the equipment.
Certification
INCERT
EN 50131-1 System requirements
EN 50131-3 Control and indicating equipment
NXG-1820-EUR: Security Grade 2, Environmental
class II
Tested and certified by ANPI vzw/asbl
Compliance labelling should be removed or adjusted
if non-compliant configurations are selected.
For EN50131-3 compliancy, do not use AUX IN.
UTC Fire & Security hereby declares that this device
European Union
is in compliance with the applicable requirements
directives
and provisions of one or more of the Directives
1999/5/EC, 2014/30/EU and 2014/35/EU. For more
information see: www.utcfireandsecurity.com or
www.interlogix.com
2002/96/EC (WEEE directive): Products marked
with this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper
recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For
more information see: www.recyclethis.info.
Contact information
www.utcfireandsecurity.com or www.interlogix.com
Customer support
For customer support, see www.interlogix.com/customer-
support or www.utcfssecurityproducts.eu
4 / 28
EL: Φυλλάδιο εγκατάστασης
Σύνοψη προϊόντος
Αυτή η μονάδα προσθέτει 10 εξόδους ρελέ σε ένα σύστημα
xGen.
Τοποθέτηση της μονάδας
1.
2.
3.
P/N 466-2716 • REV A • ISS 23MAY16