Vacuum unit CV 10 assembly instructions

Fig. 1
2.1 Fitting the wall bracket
Position the holder so that there is plenty of space above
and below the place where the vacuum unit is to be located.
Make sure there is a minimum of 500 mm (19 in) free space
above the CV 10 container. Mark the positions for the four
screw holes with a pen or similar. Then select appropriate
screws and, if necessary, wall plugs for the type of wall
surface to which the bracket is to be attached. Drill the
four holes for the wall bracket. The diameter of the screw
holes in the holder is 5 mm (0.19 in). Fit the wall bracket
with the large opening pointing upwards, see Fig. 1. Tighten
the screws so that the holder is held fi rmly in place (screws
provided).

2.3 Connecting the machine

The machine is connected with the suction pipe in the uppermost position and the exhaust
pipe in the lower position.
This connection should not be glued but can be taped when the unit is serviced at
a later date. The suction pipe socket can be fi tted to two different points depending
on the direction in which you would like to install the pipe system.
To relocate the suction pipe socket, you need to do the following:
1. Release the suction pipe socket by unscrewing the four combination Torx screws
with a Torx T20 or an ordinary screwdriver, Fig. 3.
2. Pull the socket out of the machine, see Fig. 4.
3. Loosen the plug blanking off the outlet to which you intend moving the suction
pipe socket. Unscrew the four combination Torx screws. Remove the blanking plug
from the machine.
4. Adapt (move) the suction pipe socket to the new outlet. NB! The socket is marked "Up".
Make sure the socket is fi tted with Up uppermost. Fasten the socket by fi tting and tightening the four screws, Fig. 5.
5. Fit the blanking plug to the outlet previously occupied by the suction pipe socket. Use the four screws to hold it in place.
The exhaust pipe must be fi rmly attached to the wall to ensure its connection with the socket does not loosen. Remember
that you will need to be able to turn the bent pipe in different directions to ensure a suitable pipe layout. Then connect up
the exhaust pipe and muffl er, Fig 6. Fit the central vacuum cleaner so that the exhaust pipe is as short as possible, max. 10
metres / 30 feet. Take the surroundings into consideration when positioning the exhaust. For this reason, you should always
fi t a muffl er.
For additional information concerning the assembly and installation of the pipe system and low-current lead, please refer to
the separate assembly instructions supplied with the pipe package.
6
All manuals and user guides at all-guides.com
Fig. 3
Fig. 2
2.2 Locating the vacuum cleaner on the
wall bracket
Position the vacuum unit so that the mounting bracket is di-
rectly above the wall bracket, see Fig. 2. Lower the machine
down on to the wall bracket. Make sure the corresponding
bracket on the machine is held fi rmly in place by the wall
bracket.
Fig. 4
Fig. 5
Fig. 6