8

Disassembly and disposal

9

Maintenance

10

Technical specifications

Recommended sensing range for the best performance
Sensing range max.
Light spot diameter/distance
Supply voltage U
B
Ripple
Output current I
max.
Current consumption
Communication mode
IO-Link
8025665.1C7L/2021-09-03 | SICK
Subject to change without notice
LED indicator/fault pattern
No object in beam path, no
output signal
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Efforts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
SICK sensors are maintenance-free.
We recommend doing the following regularly:
Clean the external lens surfaces
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
DISASSEMBLY AND DISPOSAL
Cause
Test input (Test) is not con‐
nected properly
WTB4FP-xxxxx1
40 mm ... 140 mm
4 mm ... 220 mm
(Typ)
1)
Ø 5 mm (50 mm) (Typ) ,
Ø 4 mm (100 mm) (Typ)
DC 10 ... 30 V
2)
≤ 5 Vss
≤ 100 mA
25 mA
COM2
1.1
O P E R A T I N G I N S T R U C T I O N S | WTB4FP MultiSwitch
Measures
Check connection of the test
input. When using female cable
connectors with LED indicators,
make sure the test input is
assigned correspondingly.
WTB4FP-xxxxx2
30 mm ... 60 mm
4 mm ... 100 mm (Typ)
Ø 2 mm (50 mm) (Typ)
DC 10 ... 30 V
2)
≤ 5 Vss
≤ 100 mA
25 mA
COM2
1.1