Characteristics; Packing Of The Mz; Packing; Storage - ITRON MZ Manual De Instrucciones

Ocultar thumbs Ver también para MZ:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
Keep this manual easily accessible for all
users . Please respect all national rules for
installation, operation and service of gas
meters .

1 Characteristics:

Turbines gas meters are flow meters . The
flow of gas turns a turbine wheel and the
rotating speed of the turbine is propor-
tional to the linear speed of the gas . The
movement is mechanically transmitted to
the totaliser through the magnetic cou-
pling . Detailed characteristics are given in
Annex 1

2 Packing of the MZ

2.1 Packing

The meter, depending on the size is de-
livered in an individual carton box or on a
wood pallet . The packaging contains the
plugs for the installed transmitters and the
lubricant when an oil pump is installed .

2.2 Storage

If the meter is not going to be used imme-
diately, it should be stored under cover in
a clean, dry environment . The caps fitted
at the inlet and the outlet pipe must stay
in place until installation . Storing tempera-
ture: -40 °C to +70°C .

2.3 Handling

Meters should be handled with care . They
must be lifted only with belts around the
main body or on the eyelets .
4
All manuals and user guides at all-guides.com

3 Installation

3.1 General recommendations:

• T he standard MZ is designed for use with
• I f the meter is equipped with an oil pump,
• ( 1) Before installation, check visually that
• ( 2) Do NOT weld pipework with a meter
• ( 3) The meter should be installed with-
Please tighten bolts in opposite pairs .
• ( 4) To ensure accuracy, The meter has
• ( 5) Transmitters connection: Gas Me-
See Annex 2 and PED information
in Annex 6
clean and non-aggressive gases . For use
with aggressive gases please contact
Itron for special versions .
turn oil tank according to the installation
position .
the meter has not been damaged during
transport .
installed .
out stress in the pipework . The flanges
must be correctly lined up . The tighten-
ing torque of the bolts must not exceed
(Nm):
M16
M20
85
170
to be installed with an inlet straight pipe
of 3 DN minimum .
ters are often installed in areas where
there is a risk that Gas will be present .
Therefore, electrical connections to me-
ters need to be made with consideration
of the use of Ex marked equipment or
otherwise approved circuits . For plug as-
signment and pulse values refer to the
main name plate .

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

002-099-4115

Tabla de contenido