TROUBLE SHOOTING
Problem
The Power Switch is in the on-
position. The Pilot Light (7)
does not illuminate.
The humidifier produces only litt-
le or no mist.
Humidity condenses on
furniture, walls or floors.
White dust
CONDITION OF SALE
As a condition of sale, the purchaser assumes
responsibility for the proper use and care of this
appliance in accordance with these printed instructions.
The purchaser or user must judge himself or herself
when to use the appliance and the length or use.
Our oral and written indications are based on
extensive tests. Our advice is given to the best of
our present knowledge, but without obligation
inasmuch as the use of the unit is beyond our direct
influence. No liability can be assumed for any damages
caused by improper use (such as inadequate
cleaning, decalcifying filter exchanged too late, free
discharge of humidity impeded atomization of
chemical additives or liquids other than pure tap
water etc.). No additives must be put in the water
as the unit could suffer damage and health risks
could not be excluded as well.
All manuals and user guides at all-guides.com
ENGLISH
Possible Cause
1. The plug is not plugged in.
2. There is no power at the
outlet.
1. No water in Tank (3).
2. The unit is not placed on a
firm, level surface.
3. The Water Tank (3) was
washed with a washing liquid
and not rinsed thoroughly.
4. Mineral deposits on Water
Sensor (16) or Nebulizer (17).
5. Blower not operating (10).
6. Cartridge (13) is clogged.
7. Nebulizer not functioning.
1. The relative humidity in the
room is too high.
1. The water is too hard.
2. The Cartridge (13) is
exhausted.
NOTE: IF YOU EXPERIENCE A PROBLEM
WITH YOUR HUMIDIFIER PLEASE SEE
WARRANTY FOR INSTRUCTIONS. PLEASE
DO NOT ATTEMPT TO REPAIR THE HUMI-
DIFIER YOURSELF. DOING SO WILL VOID
THE WARRANTY AND COULD CAUSE
DAMAGE OR PERSONAL INJURY.
Technical specifications are subject to change.
9
Solution
1. Plug the humidifier in.
2. Check the circuits and fuses
or ask a specialist.
1. Fill the Water Tank (3).
2. Place the humidifier on a firm,
level surface.
3. Empty the water tank (3) and
rinse thoroughly with warm
water.
4. Carefully clean or disinfect
Water Sensor (16) and
Nebulizer (17).
5. Ensure water in Reservoir
(15) is adequate to immerse
Water Sensor (16).
6. Replace used Cartridge with
a new one (13).
7. Ask a specialist and follow
the instructions in the
warranty manual.
1. Follow the "Operating
Instructions".
1. Follow the instructions under
"Demineralization Cartridge
AC-819E" and use the extra
filter KF-520E.
2. Replace the exhausted Car-
tridge (13) with a new one.