Switch Lock Function; Automatic Drain Pan Flush - Hoshizaki DCM-60KE Manual De Instrucciones

Dispensador de cubitos de hielo
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 64
ENGLISH
3) To deactivate the portion control, press the portion control switch again. The display goes off.
4) Replace the front cover in its correct position.
[b] Adjusting portion control
1) Remove the front cover.
2) Press and hold the portion control switch on the control panel for 3 seconds. The display shows the current portion control
setting for ice dispensing.
3) Press the flashing ice (-) switch or water (+) switch on the operation panel to adjust the amount of ice. The value in the display
decreases or increases by "1" every time the switch is pressed (e.g. "06" = 60g).
[DCM-60/120KE]
4) Press the portion control switch on the control panel. The display illuminates "PORTION".
5) Replace the front cover in its correct position.
[DCM-60/120KE-P]
4) Press the portion control switch on the control panel. The display goes off and illuminates the setting again when it is stored.
Then, the display shows the current portion control setting for water dispensing.
5) Press the flashing ice (-) switch or water (+) switch on the operation panel to adjust the amount of water. The value in the
display decreases or increases by "1" every time the switch is pressed (e.g. "15" = 150mL).
6) Press the portion control switch on the control panel. The display goes off and illuminates the setting again when it is stored.
Then, the display illuminates "PORTION".
7) Replace the front cover in its correct position.

5. SWITCH LOCK FUNCTION

Pushing the lock switch on the control panel locks the ice switch, ice & water switch, and water switch operations. The switch
lock function is deactivated in the default setting.
1) Remove the front cover.
2) Select your dispensing choice by pushing ice switch, ice & water switch, or water switch on the operation panel. The selected
switch flashes. Press the lock switch on the control panel. The lock lamp on the operation panel lights up.
3) To deactivate the switch lock function, press the lock switch again. The lock lamp goes off.
4) Replace the front cover in its correct position.

6. AUTOMATIC DRAIN PAN FLUSH

The automatic drain pan (and drain circuit) flush is available just after the operation switch is turned on and at the predetermined
time intervals. The automatic drain pan flush is deactivated in the default setting.
The time interval for the automatic drain pan flush is adjustable as follows:
Default Setting
Every 6 hours
1) Remove the front cover.
2) Press and hold the drain switch on the control panel for 3 seconds. The display shows the current time interval.
3) Press the flashing ice (-) switch or water (+) switch on the operation panel to adjust the time interval. The value in the display
decreases or increases by "1" every time the switch is pressed (e.g. "08" = every 8 hours).
4) Press the drain switch on the control panel. The display illuminates "DRAIN PAN FLUSH".
Adjustable Range
Every 1 - 24 hours (in 1 hour steps)
8

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dcm-60ke-pDcm-120keDcm-120ke-p

Tabla de contenido