Urmet Sinthesi Steel 1083/64 Manual Del Usuario página 26

Microaltavoz externo audio 2voice
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

If instead the door unit is confi gured as main unit, then the buttons are automatically associated to the column
0, which simplifi es the installation of main units in single column systems.
Instead, if the door unit is confi gured as main unit and several columns are present in the system, an
association must be created between the buttons and the users of the different column proceed as follows:
Access advanced confi guration by turning the two rotary switches to position 99 (the yellow LED will
light up).
Set the ID dip-switch to the code of the fi rst column in the system (column 0 typically).
Press the button corresponding to user 0 of the selected column. All the subsequent buttons will be
automatically associated to the users of the column itself in sequence.
Repeat the operation on all the columns.
Reset the ID dip-switch in start position.
To quit advanced confi guration, turn the two rotary switches to the door opening line and the guaranteed
conversation time setting positions. The yellow LED will go out.
Example:
System with 3 columns, the fi rst with 4 users, the second with 6 users and the third with 8 users.
26
P5÷P8
P9÷P12
1083/17 (1)
P1÷P4
P13÷P16
INPUT
OUTPUT
P5÷P8
P9÷P12
1083/17 (4)
P1÷P4
P13÷P16
OUTPUT
DS1083-058B

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

1083/64

Tabla de contenido