Important! The fitting must be installed,
flushed and tested after the valid norms.
Assembly
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer in
position on the basin.
3. Slide the fixation piece including the washer over
the threaded pins and tighten the nuts..
4. Connect the supply pipes to the isolation valves;
cold right - hot left.
5. 32004000: Zugstangemit Ablaufventil verbin-
den.
The hot and cold supplies must be of equal pressures.
Operation
The mixer is activated by lifting the lever handle.
Turning to the left = warmer water,
turning to the right = cooler water.
Technical Data
This mixer series-produced with water-
dimmer (flow limiter)
Rate of flow with waterdimmer:
Rate of flow without waterdimmer:
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Hansgrohe single lever mixers can be used together
with hydraulically and thermically controlled continuous
flow heaters if the flow pressure is at least 1.5 bars.
If the continuous water heater causes any problems or
there is not enough flow of water, the waterdimmer
(5a) located behind the aerator must be removed.
6
English
To adjust the hot water limiter on single lever mixers,
please see page 13.
No adjustment is necessary when using a continuous
flow water heater.
Spare parts (see page 3)
1
1.1 screw cover
2
3
4
5
6
7
Special accessories
X
7 l/min 3 bars
12 l/min 3 bars
max. 10 bars
1 - 5 bars
16 bars
max. 80° C
65° C
handle
flange
nut
cartridge cpl.
aerator cpl.
pop up rod
fixing set
special tool set
(order as an extra))
32091000
94191000
94192000
94194000
92730000
13912000
92620000
96016000
58085000