4 Technical data
Right of technical changes reserved.
Rated
100 V
voltage
Rated power
710 W
en
input, UD 16
Rated current
7.5 A
input, UD 16
Rated power
650 W
input, UD 30
Rated current
6.9 A
input, UD 30
Power tool
Mains frequency
Weight of tool without side handle
Weight in accordance with EPTA
procedure 01/2003
Dimensions (L x W x H)
Speed in 1st gear under no load
Speed in 2nd gear under no load
Chuck ∅
Maximum torque, 1st gear
Maximum torque, 2nd gear
Speed control
Forward / reverse
Tightening torque for changing
chuck
NOTE
The vibration emission level given in this information sheet has been measured in accordance with a standardised test
given in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment
of exposure. The declared vibration emission level represents the main applications of the tool. However if the tool is
used for different applications, with different accessories or poorly maintained, the vibration emission may differ. This
may significantly increase the exposure level over the total working period. An estimation of the level of exposure to
vibration should also take into account the times when the tool is switched off or when it is running but not actually
doing the job. This may significantly reduce the exposure level over the total working period. Identify additional safety
measures to protect the operator from the effects of vibration such as: maintain the tool and the accessories, keep
the hands warm, organisation of work patterns.
Noise and vibration information (measured in accordance with EN 60745‑1):
Typical A-weighted sound power level
Typical A-weighted emission sound pressure level
Uncertainty for the given sound level
Triaxial vibration values (vibration vector sum)
Screwdriving without impact action, a
Uncertainty (K)
18
110 V
120 V
710 W
6.9 A
8 A
650 W
6.5 A
6.5 A
UD 16
50...60 Hz
2.4 kg
2.6 kg
342 mm x 86 mm x 205 mm
900/min
2,500/min
1.5...13 mm
80 Nm
29 Nm
Electronic, by way of the control
switch
Switching lever with interlock to
prevent switching while running
120 Nm
97 dB (A)
86 dB (A)
3 dB (A)
Measured in accordance with EN 60745‑2‑2
< 2.5 m/s²
h
1.5 m/s²
220 V
230 V
710 W
710 W
3.5 A
3.1 A
650 W
650 W
3.1 A
2.9 A
UD 30
50...60 Hz
2.3 kg
2.5 kg
337 mm x 86 mm x 205 mm
1,200/min
3,300/min
1.5...13 mm
51 Nm
18.5 Nm
Electronic, by way of the control
switch
Switching lever with interlock to
prevent switching while running
120 Nm
240 V
710 W
3.1 A
650 W
2.9 A