Commissioning, Operation; Electrical Connection; Pin Assignment - WIKA TF44 Manual De Instrucciones

Sensor de temperatura superficial con cable de conexión
Ocultar thumbs Ver también para TF44:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5. Transport, packaging ... / 6. Commissioning, operation
Store the instrument in its original packaging in a location that fulfils the conditions listed above. If
the original packaging is not available, pack and store the instrument as described below:
1. Wrap the instrument in an antistatic plastic film.
2. Place the instrument, along with shock-absorbent material, in the packaging.
GB
3. If stored for a prolonged period of time (more than 30 days), place a bag containing a
desiccant inside the packaging.
WARNING!
Before storing the instrument (following operation), remove any residual media. This
is of particular importance if the medium is hazardous to health, e.g. caustic, toxic,
carcinogenic, radioactive, etc.

6. Commissioning, operation

6.1 Mounting
The mounting of the contact temperature sensor must be made in such a way that temperature
does not exceed or drop below the permissible operating temperature limits (environment,
medium) with respect to convection and thermal radiation.

6.2 Electrical connection

WARNING!
Only connect when the system is powered down!
Cables and wires
Leads with bare ends must be finished with end splices.
The cables used must comply with the respective requirements in terms of stability and
temperature.
Connecting cables must be run so that any mechanical damage is prevented.

6.3 Pin assignment

2-wire connection
10
3-wire connection
red
white
4-wire connection
red
red
white
WIKA operating instructions model TF44
red
red
white
white

Publicidad

Tabla de contenido
loading

Tabla de contenido