When charging is complete remove the charging adaptor
form the mains power socket.
Remove the charging jack plug from the charging socket
(9) and store in a safe place.
Note: This unit is delivered in a partially charged state – you
must fully charge it before using it for the first time.
Initial AC charge should be for 48 hours.
Charging/Recharging Using the AC Charger and a
Standard Household Extension Cord (Not included)
(Charging Method for 120V ~ 50/60Hz Units)
1. Lift the AC adapter cover located on the front of the unit
and connect an extension cord to the unit. Plug the other
end of the cord into a standard AC wall outlet.
2. Charge until one red, two yellow and one green LED
Battery Status Indicators light or flash.
3. Once fully charged, disconnect the extension cord.
Note: The unit cannot be overcharged using the AC method.
Using the unit as a jump-starter
Warning! Make sure that the vehicle is in neutral with the
parking brake applied.
Note: If your connections are incorrectly made, the unit will
beep continuously and the red reverse polarity indicator (4)
will illuminate.
Warning! Make sure that the cables are not in the path of
moving belts or the fan.
1. Turn off the vehicles ignition and all accessories before
making any connections.
2. Make sure that the units ON/OFF switch (5) is turned OFF.
3. The following procedure is for a negative earth system
ie the negative battery terminal is connected to the chassis.
4. Connect the positive (+) red clamp to the vehicle's
positive battery terminal.
5. Connect the negative (-) black clamp to chassis or a solid,
non-moving, metal vehicle component or chassis part.
Never clamp directly to negative battery terminal or moving
part. Refer to the automobile owner's manual.
6. Turn the unit's ON/OFF switch (5) to the ON position.
7. Start the vehicle and crank the engine in 3 to 6 second
bursts.
If the engine doesn't start within 6 seconds let the
units internal battery cool for 3 minutes before
making another attempt.
8. When the vehicle starts, turn the unit's ON/OFF switch
(5) to the OFF position.
9. Leave the vehicle's engine running.
10. Disconnect the (-) black clamp connected to the engine
or chassis first, followed by the (+) red clamp that is
connected to the battery positive (+) terminal.
11. Carefully press the negative (black) jumper cable wire
into the storage channel starting at the end furthest from
All manuals and user guides at all-guides.com
12. Clamp the negative (black) clamp onto the clamp holder.
13. Carefully press the positive (red) jumper cable wire into
14. Clamp the positive (red) clamp onto the clamp holder.
15. Charge the unit as soon as possible.
Note: After each use, clean the battery clamps (2) and be
sure to remove any battery fluid that will cause corrosion of
the clamps (2). Keep the battery charger cords loosely coiled
during storage to prevent damage to the cords.
Using the LED area light
The LED area light (1) will operate up to 50 hours on a full
charge. The LED area light's operating life is 100,000 hours.
Make sure that the LED area light is turned off while the unit
is being charged or stored.
Using the USB Port
1. Push the USB Power Port On Push button to turn the
2. Plug the USB-powered device into the inverter's USB
Notes: This unit's USB Power Port does not support data
communication. It only provides 5 volts/500mA DC power to
an external USB-powered device.
Make sure the USB Charging Port ON/OFF Push button is in
the OFF position when the unit is being recharged or stored.
Some household USB-powered electronics will not operate
with this unit.
Using the inflator (only for JU450CB)
17
the clamp.
the storage channel starting at the end furthest from the
clamp.
Press the LED area light on/off button (3) on the top panel
of the unit to turn the LED area light (1) on.
Press the LED area light on/off button (3) again to turn
the LED area light (1) off.
USB Port ON.
Charging Port and operate normally.
Warning! When using the inflator:
Do not use the inflator when the charger is connected to
the mains.
Do not direct the nozzle at animals or bystanders.
Never leave the compressor unattended when running.
Only use the adaptors supplied.
Should the unit run over an extended period of time it
may overheat and cause the thermal trip to activate.
When this occurs switch the compressor off and allow to
cool for 30 minutes.
Keep the compressor stored out of reach of small children.
The gauge is intended as a guide only. Tyre pressures
should be regularly checked with a certified gauge.
Do not over inflate any object as this may cause a risk
of injury.
Do not operate inflator continuously for extended periods
of time (approximately 10 minutes, depending on ambient
temperatures), as it may overheat. In such event, inflator
ENGLISH