Wiring Diagram for Operating Mode 1

To operate the relay box in Operating Mode 1 (non-encoded data), all DIP switches (1
through 7) must be open ("Off").
B6
B5
B4
B3
B2
B1
Combics application: "Basic Filling"
Coarse flow:
Fine flow:
Within tolerance:
Filling active:
A10 Ground (customer installation)
A9 Supply voltage (customer installation)
A1 UNI-IN
Less than (<)
Equal to (=)
Greater than (>)
Ground (from control device)
UNI
MINOR: Less than (<)
PARES: Equal to (=)
MAJOR: Greater than (>)
SET
Control signal: Less than (<)
Control signal: Equal to (=)
Control signal: Greater than (>)
Control signal: Set
Installation Instructions | Installationsanleitung
2
3
4
Set
5
Power supply
(from control device)
Ground
(from control device)
Relay 2
Relay 3
Relay 4
Relay 5
C1
C3
7