23
1 Bit
1 Byte
1 Byte
24
1 Byte
1 Byte
1 Byte
1 Byte
25
1 Byte
1 Byte
26
2 Bytes
27
2 Bytes
28
1 Bit
29
1 Bit
30
2 Bytes
31
4 Bytes
32
2 Bytes
33
1 Bit
34
1 Bit
35
1 Bit
36
1 Bit
37
14 Bytes
38, 42
2 Bytes
39, 43
1 Bit
40, 44
1 Bit
41, 45
1 Bit
46, 52
1 Bit
1 Bit
47, 53
1 Bit
http://www.zennio.com
E
C - - W -
DPT_Step
E
C - - W -
DPT_Scaling
E
C - - W -
DPT_Scaling
E
C - - W -
DPT_Scaling
E
C - - W -
DPT_Scaling
S
C T R - -
DPT_Scaling
S
C T R - -
DPT_Scaling
S
C T R - -
DPT_Scaling
S
C T R - -
DPT_Scaling
S
C T R - -
DPT_Value_Temp
E
C - - W -
DPT_Value_Temp
E
C - - W -
DPT_Switch
S
C T R - -
DPT_State
E
C - - W -
DPT_TimePeriodSec
E/S
C T R W -
DPT_LongDeltaTimeSec
E/S
C T R W -
DPT_TimePeriodHrs
S
C T R - -
DPT_Alarm
S
C T R - -
DPT_Alarm
S
C T R - -
DPT_Alarm
S
C T R - -
DPT_Alarm
S
C T R - -
DPT_String_ASCII
S
C T R - -
DPT_Value_Temp
S
C T R - -
DPT_Alarm
S
C T R - -
DPT_Alarm
S
C T R - -
DPT_Alarm
E
C - - W -
DPT_Enable
C T - - -
DPT_Switch
C T - - -
DPT_Switch
0/1
[AA] Lamas: control por pasos
0% - 100%
[AA] Lamas: control porcentaje
0% - 100%
[AA] Lamas: control porcentaje
0% - 100%
[AA] Lamas: control porcentaje
0% - 100%
[AA] Lamas: control porcentaje
[AA] Lamas: posición porcentaje
0% - 100%
(estado)
[AA] Lamas: posición porcentaje
0% - 100%
(estado)
[AA] Lamas: posición porcentaje
0% - 100%
(estado)
[AA] Lamas: posición porcentaje
0% - 100%
(estado)
-273,00° - 670760,00°
[AA] Temperatura medida por el AA
-273,00° - 670760,00°
[AA] Temperatura de referencia externa [0 ... 70] ºC
0/1
[AA] Apagado automático
0/1
[AA] Apagado automático (estado)
0 - 65535
[AA] Apagado automático: retardo
-2147483648, 2147483647
[AA] Tiempo de operación (s)
0 - 65535
[AA] Tiempo de operación (h)
0/1
[AA] Error interno: comunicación
0/1
[AA] Error interno: sin respuesta
0/1
[AA] Error interno: respuesta incorrecta Respuesta recibida con errores
0/1
[AA] Error unidad AA: error activo
[AA] Error unidad AA: código de error
-273,00° - 670760,00°
[Ex] Temperatura actual
0/1
[Ex] Sobreenfriamiento
0/1
[Ex] Sobrecalentamiento
0/1
[Ex] Error de sonda
0/1
[Ex] Bloquear entrada
0/1
[Ex] [Puls. Corta] 0
0/1
[Ex] [Puls. Corta] 1
KLIC-MITT v2
0 = Disminuir; 1 = Aumentar
[0]% = Mov.; [0.4...25.1]% = P1;
[25.5...50.2]% = P2; [50.6...75.3]% =
P3; [75.5...100]% = P4
[0.4...25.1]% = P1; [25.5...50.2]% =
P2; [50.6...75.3]% = P3;
[75.5...100]% = P4
[0]% = Mov.; [0.39...20]% = P1;
[20.39...40]% = P2; [40.39...60]% =
P3; [60.39...80]% = P4;
[80.39...100]% = P5
[0.39...20]% = P1; [20.39...40]% =
P2; [40.39...60]% = P3; [60.39...80]%
= P4; [80.39...100]% = P5
Mov. = 0%; P1 = 25.1%; P2 = 50.2%;
P3 = 75.3%; P4 = 100%
P1 = 25.1%; P2 = 50.2%; P3 =
75.3%; P4 = 100%
Mov. = 0%; P1 = 20%; P2 = 40%; P3
= 60%; P4 = 80%; P5 = 100%
P1 = 20%; P2 = 40%; P3 = 60%; P4 =
80%; P5 = 100%
Temperatura del sensor interno (ºC)
0 = Desactivar; 1 = Activar
0 = Inactivo; 1 = Activo
[0 ... 3600] s (0 = Deshabilitado)
Tiempo en segundos
Tiempo en horas
Incapaz de establecer comunicación con
el AA
No se recibe respuesta del AA
Error en la unidad de AA
Ver manual de la unidad de AA
Valor del sensor de temperatura
0 = No alarma; 1 = Alarma
0 = No alarma; 1 = Alarma
0 = No alarma; 1 = Alarma
0 = Desbloquear; 1 = Bloquear
Envío de 0
Envío de 1
Soporte técnico:
http://support.zennio.com