SHUR-DRI SDPT20 Manual De Instalación página 5

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
TESTING FOR WATER CELL LEAKAGE
Step 1. Disconnect power to pump.
Step 2. Drain water from tank water cell by opening
faucet closest to tank.
Step 3. Remove valve cap and release all pressure by
depressing valve core. When air stops coming
from valve, remove valve core to release
remaining pressure.
Step 4. Disconnect piping from elbow on tank cover
flange.
Step 5. Carefully turn tank upside down or lay on its side.
Retained water in tank may cause sudden
weight shift when lowering. Support tank so it cannot
fall when being lowered or inverted.
Step 6. If water cell leaks, water will run out of valve. If
so, replace water cell.
Step 7. If replacing water cell, be sure air and water
pressures are relieved before removing cover
flange. When reassembling cover flange, do
not tighten nuts or mounting studs more than
85 in-lbs. (9.6 Nm).
NOTICE: When using metal pipe with plastic fittings use
only Teflon tape or Plasto-Joint Stik
Catalog
Number
SDPT20
SDPT20H
SDPT36
SDPT52
SDPT85
SDPT119
* Length overall; this model is a horizontal tank.
For parts or assistance, call SHUR-DRI Customer Service at
on male threads.
1
Product Information – Pre-Charged Tanks
Catalog
20-40 PSI
Number
(138-276kPa)
SDPT20
6.9 (26.1)
SDPT20H
6.9 (26.1)
SDPT36
12.7 (48.1)
SDPT52
18.3 (69.3)
SDPT85
30.0 (113.6)
SDPT119
41.3 (156.3)
Maximum
Equivalent
Capacity
to Standard
US Gals (L)
Tank US Gals (L)
19 (72)
42 (159)
19 (72)
42 (159)
35 (132)
82 (310)
50 (189)
120 (454)
85 (322)
220 (833)
119 (450)
320 (1211)
Pressure
Pressure
Gauge
Switch
From Well
Figure 5: Typical installation with vertical pre-charge tank and
submersible well pumps
NOTICE: Most standard tanks have separate inlet and
outlet ports. Pre-charge tanks have one port serving both
functions. When replacing standard tank with a pre-
charge tank, run pipe from pump into a tee as shown.
2nd leg of tee goes to tank elbow; 3rd leg goes to exist-
ing service.
Drawdown - Gals (L)
30-50 PSI
40-60 PSI
(207-345kPa)
(276-414kPa)
5.8 (22)
5.0 (18.9)
5.8 (22)
5.0 (18.9)
10.7 (40.5)
9.3 (35.2)
15.5 (58.7)
13.4 (50.7)
26.0 (98.4)
22.0 (83.3)
35.4 (134.0)
31.0 (117.3)
Tank
Tank
Diameter
Height
(mm)
(mm)
16" (406)
30-1/8" (765)
16" (406)
*24-5/8" (625)
20" (508)
36-1/4" (921)
24" (610)
34-3/4" (883)
24" (610)
54" (1372)
24" (610)
68" (1727)
1-800-535-4950
To service
Pressure
Relief Valve
Tank
Discharge
Tapping
1"
1"
1"
1-1/4"
1-1/4"
1-1/4"
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sdpt20hSdpt36Sdpt52Sdpt85Sdpt119

Tabla de contenido