MAINTENANCE & CARE
12
12B
12E
12D
12C
12 FLUSHING & AERATOR CLEANING
After installation is complete, remove Aerator Housing (12A). Lift Handle (12B) on
and allow both hot and cold water to run for at least one minute each. While water is
running, check for leaks. To clean the aerator, disassemble Aerator Housing (12A) by
separating the Aerator Shell (12C), Basket (12D), and Washer (12E). Once parts have
been cleaned, reassemble by reversing steps.
13
13B
13C
13 HANDLE REMOVAL
Turn off water before proceeding! With valves in closed position, detach Decorative
Button (13A), unscrew Fastener (13B), and remove Handle (13C) from Valve Stem
(13D).
12A
13A
13D
ENGLISH
14
14 CARTRIDGE REPLACEMENT
Turn off water supplies and relieve pressure before working on your faucet. Remove
handle (see figure 13). Remove the Dome Cap (14A) by unscrewing counterclockwise.
Using pliers, unscrew the retainer ring (14B). Carefully remove the Cartridge (14C) by
pulling it straight up and out. Reassemble valve by reversing steps.
CAUTION: Maintenance
DISASSEMBLY
1.
Replacement parts may be available at the store where you purchased
your faucet.
2.
When replacement parts are not available, please write or call Price
Pfister Consumer Service.
3.
Always turn off water and relieve pressure before working on your
faucet.
NOTE: Trim Care
Cleaning Instructions:
For all Handles and decorative finishes, use only a soft damp
cloth to clean and shine. Use of polish, detergents, abrasive
cleaners, organic solvents or acid may cause damage. Use of
other than a soft damp cloth will nullify our warranty!
Special Trim:
Trim products which contain Porcelain or other similar
substance are not acceptable for public areas or Commercial
use. Installation of Said Trim is at Users Risk!
1–800–PFAUCET (1–800–732–8238)
For Toll-Free Pfaucet information call
1–800–PFAUCET (1–800–732–8238)
or visit www.pricepfister.com
• Installation Support
• Care and Warranty Information
4
14B
14A
14C