nedis DTCTCS10WT Manual Del Usuario página 8

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 30
Activating the batteries
The batteries are activated when attached to the
bracket for the first use.
-
The product must be used with the matching
bracket. The product does not work when used
separately.
Choosing a location (image B & C)
For safe use it is recommended to install the product in
areas with a source of combustion where CO and smoke
will move upwards quickly.
The product can be installed in:
• Every sleeping area.
• Both ends of a hallway longer than 12 m.
• Every room where a furnace, a heat source and/or
other burning devices are located.
• Every room where multiple people spend several
consecutive hours.
• Install at least one product on each floor of a
multi-level home.
In areas with a source of combustion:
On the ceiling:
• At least 3 m away from the CO-source.
• At least 30 cm away from surrounding walls.
• At a central point in the room.
• Not in turbulent air (near windows, ceiling fans or air
conditioners).
The product can also be installed on a sloped ceiling.
4
-
Do not install in the tip of a sloping ceiling as
smoke-free air can collect in these areas.
In sleeping areas:
• Not in turbulent air (near windows, ceiling fans or air
conditioners).
• Not behind objects (curtains or closets).
Other areas:
• Not in turbulent air (near windows, ceiling fans or air
conditioners).
• Not behind objects (curtains or closets).
For optimal CO detection install the product at
4
breathing height.
For optimal smoke detection install the product at a
4
minimal height of 1.80 m.
Do not install the product:
• in dirty, greasy or dusty areas.
• in temperatures below 0 ºC.
• in temperatures above +40 ºC.
• in turbulent air (near ceiling fans, air conditioners or
open windows).
• within 3 meters of a high humidity source.
• within 1.5 meters of kitchen appliances.
• within 6 m of a furnace or fuel burning heat sources.
• behind objects like curtains or closets.
• within 1 m of fluorescent light.
Installing/Mounting the product (image
D & E)
1. Place A
in the desired location.
4
Follow steps 2. - 6. for stone/concrete surfaces. Continue
to step 5. for wood surfaces.
2. Use A
4
to mark the drill locations with a pencil
(70mm in between the two holes).
3. Drill two Ø 5 mm holes.
4. Insert the plugs into the holes.
5. Fasten the mounting bracket with the screws.
6. Turn A
clockwise to attach it to A
3
Do not overtighten the screws, this will deform the
4
bracket.
Testing the product
The product must be tested once a week to ensure
proper operation. Press and hold the test/silence
button. A
blinks red. Hold until the product emits
1
three long beeps and four long beeps.
8
4
.

Publicidad

Tabla de contenido
loading

Tabla de contenido