Installation and connection
Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries.
Protective measures:
• Only operate the unit with the protection hood fitted.
• Ensure that the unit is installed water-tight with a safety distance from the water of a minimum of 2 m.
Connecting the antenna
How to proceed:
C
1. Remove the blind plug and screw the antenna into place.
2. Align the antenna.
Set-up the unit
How to proceed:
B
• Install the unit at least 2 m from the edge of the pond.
D
1. Remove the protection hood from the unit.
2. Insert the ground stake by approx. ¾ of its length into the ground.
3. Slide the device onto the ground stake.
4. With the unit, push the ground stake fully into the ground.
5. Check its stability.
Connecting the power supply
How to proceed:
E
Unit version with power plug:
• Push the coupling of the power cable onto the unit plug.
F
Unit version with power cable:
• Connect the unit to the power supply.
– Work on the power supply may only be carried out by a qualified electrician.
– Adhere to the pin assignment specified on the power cable label.
– Only use wires with wire end ferrules for connection.
Connect the units to the power supply distributor
How to proceed:
1. Choose a suitable socket (see fig. above) and insert the unit power plug into the socket.
– Check that your OASE unit may be connected to this socket. For this purpose, consult the instructions of use of
the unit you wish to connect.
– The following applies: Units powered via a transformer may not be connected to a socket with dimmer function.
G
2. Fit the protection hood.
All manuals and user guides at all-guides.com
1 Socket 1, switchable (max. 10 A / 2000 W)
2 Socket 2, switchable (max. 10 A / 2000 W)
3 Socket 3, switchable (max. 10 A / 2000 W)
4 Socket 4, switchable and dimmable (max. 40 A / 320 W)
Note: Ensure that the total output of 16 A / 3600 W is not exceeded!