MAINTENANCE

It is envisaged the maintenance of the VIARIS chargers should be very low,
limited to:
Cleaning Tasks.
Operation voltage and input voltage checks.
Recommended annual service.
For cleaning and checking equipment connections charger MUST be
disconnected from power supply.
For the external cleaning of the equipment, it is recommended to use
a soft, dry cloth, e.g. a microfiber cloth. Do not use abrasive materials
or detergents.

TECHNICAL CHARACTERISTICS

Feeding
Nominal frequency
Power
Self-consumption
vacuum
load function
Charging modes (depending on model) Modes 1 and 2 according to EN 61851-1
Connector cable
Communication Wi-Fi
Closing of the envelope
Protection class
Degree of protection
Degree of mechanical protection
DRC-DD
Activation/Stop modes
Type of terminals
Peeling length
Operating temperature
|
| Depending on characteristics label.
|
Single-phase
4 W
7 W
(Schuko)
Mode 3 according to EN 61851-1
Type 2. Load mode 3: according to EN
62196-2
802.11 b/g/n
with screws
Case II. Insulating envelope
IP54 according to EN 60529
IK10 according to EN 62262
6 mA protection.
Touch or RFID configurable by App
Terminals with screw
12 mm
-30 °C to + 50 °C
80
Tree-phase
4 W
14 W