Descargar Imprimir esta página

Quantum 2U Guia De Inicio Rapido página 2

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 13
2U Rackmount Quick Start Guide
W
: For maximum stability, the equipment rack
ARNING
should be securely bolted to the floor per the rack
manufacturer's recommendations.
After installing components in the equipment rack,
do not pull out more than one component on its
slide rails at a time. If the equipment rack is not
securely bolted to the floor, the weight of more than
one extended component could cause the
equipment rack to become unstable, tip over, and
cause damage, serious bodily injury, or death.
Connecting the Interface and Power
Cables
1 Shut down and turn off the selected host server. Turn
off all attached accessory devices, such as printers and
other SCSI devices.
2 Connect the interface and power cables to the back of
the 2U Rackmount, following the instructions below for
the type of interface you are using.
N
: Be sure to connect the cables on the same
OTE
side of the 2U Rackmount as the tape drive(s)
you will be using.
SCSI (SDLT 320, SDLT 600, DLT-S4, LTO-3) (see
figure
2)
a) Connect one end of the SCSI cable to one of the
SCSI connectors on the back of the
2U Rackmount. Connect the other end of the
SCSI cable to the host.
b) Connect the SCSI terminator to the adjacent
SCSI connector on the back of the 2U
Rackmount.
c) Each SCSI device must have its own unique SCSI
ID. Change SCSI ID(s) if necessary.
Note: Any time you change the SCSI ID, you
must turn the drive power off and then back on
using the power button on the front of the 2U
Rackmount.
d) Connect the power cable.
Fibre Channel (SDLT 600, DLT-S4) (see
a) Remove the protective cap(s) from the Fibre
Channel port on the back of the 2U Rackmount.
b) Remove the protective covers from the ends of
the Fibre Channel cable.
c) Connect one end of the Fibre Channel cable to
the Fibre Channel port on the back of the
2U Rackmount. Connect the other end of the
Fibre Channel cable to the host.
d) Connect the power cable.
All manuals and user guides at all-guides.com
0
figure
3)
Figure 2 SCSI Connections
Power cable
Figure 3 Fibre Channel
Connections
Power cable
3 Plug in the power cable to the nearest properly
grounded power outlet.
4 Turn on the 2U Rackmount by pressing and holding the
power button on the front panel for one second. The
green power LED should illuminate. See
C
:
An illuminated fan LED (the left LED on the
AUTION
front panel) indicates a fan failure (see
Confirm that this has not occurred. If the fan LED is
illuminated, contact Quantum (www.quantum.com).
Figure 4 Power Button and Fan
LED
5 Turn on any other devices you turned off earlier.
6 Turn on the host server.
SCSI
terminator
SCSI
cable
Fibre
Channel
cable
figure
4.
figure
4).
Power button
Power LED
Fan failure LED
2

Publicidad

loading