Table 2: Error codes
Error code(s)
Description
1, 2 , 3
Internal battery charger
problem.
4
Temperature too low.
5
Temperature too high
6
Too many ampere
hours charged.
8
Voltage increase
insufficient.
If the cause of the failure has been removed, the battery charger can be restarted by
disconnecting and reconnecting the mains .
6. Specifications
-Go
c
specifications / model
Supported batteries
Battery capacity range
Mains voltage
Mains frequency
Output voltage range
Output current range
Maximum output power *
Efficiency
Protections
Dimensions
Charge status indication
Use
Operational temperature
range *
Storage temperature
Cooling
Maximum humidity
Safety class
Regulations
Standards
* At elevated ambient temperatures or if there is no sufficient cooling, the output current
can be reduced.
Possible causes and solution(s)
Restart battery charger. If the error is repeated
Consult Your supplier.
Move to a warmer environment and restart the
charging.
Let the charger cool down for 15 minutes and
restart the charging. If the problem persists
please consult Your supplier.
1: Connected a battery with higher capacity then
specified.
2: Unknown problem. Please consult Your
supplier.
Possibly a defective battery.
Please consult Your supplier.
4A
6A
Lead Acid (Gel/ AGM) 24V or 2 x 12V
25-40Ah
40-60Ah
220-240Vac
0.25 – 4A
0.25 – 6A
120W
180W
> 90% at full load and 230Vac
Polarity , Output voltage , Temperature
Passive
Passive
95% (non condensing)
CE (LVD, EMC, RoHS)
EN60335-2-29 , EN12184 , ISO7176-14, EN60601-1-2
7
8A
10A
60-85Ah
70-105Ah
(single phase)
nominal,
50/60 Hz
24V nominal
0.25 – 8A
0.25 – 10A
240W
300W
210 x 175 x 65mm
2 LEDs
Indoor use only
0 – 40°C
-15 - +50°C
Passive
Active (Fan)
II
English
English
English
English
12A
80-125Ah
0.25 – 12A
360W
Active (Fan)