Panel reader settings
Menu name
Options
BLUETOOTH®
Auto**
Manual
Off
FIND BT DEVICES
PAIRED DEVICES
DUPLICATES
On**
Off
OUTPUT MODE
Single**
Cont (Continuous)
DATA FORMAT
Dec 1 (Decimal 1)**
Dec 2 (Decimal 2)
Hex (Hexadecimal)
ISO
DIAGNOSTICS
Supply voltage
Antenna voltage and
tuning value
Noise level
Read rate
SOFTWARE VERSION
LANGUAGE
ENGLISH
ESPAÑOL
PORTUGUÊS
FRANÇAIS
DEUTSCH
Default settings marked **
Description
The panel reader will automatically connect to previously used devices or other
Tru-Test devices.
This setting should be used when connecting to an Android* smartphone
Bluetooth
Disables the
wireless connection.
Allows you to manually search for other
Lists previously paired devices. Select from this list to connect to another device.
will not
The panel reader
record the same EID twice in the same session.
will
The panel reader
record the same EID twice in the same session.
The panel reader will only record and send the same EID
The panel reader will record only once but send the same EID
Data format changes the way that EIDs are stored and output from the panel
reader.
Standard decimal format with a space between the country (or a manufacturer's,
possibly shared) code and the national identification (or a manufacturer's unique
within series) code e.g. 826 123456789012.
Decimal format used in some countries with no space between the country (or a
manufacturer's, possibly shared) code and the national identification (or a
manufacturer's unique within series) code e.g. 826123456789012.
e.g. 8000F58000000001.
Complies with ISO 24631-6 e.g. 1000000826000000123456.
There are four diagnostics screens which provide troubleshooting information.
Select NEXT to scroll through the screens. If the values fall outside the normal
Section 10 - Troubleshooting.
range, see
The power supply voltage is displayed and should be followed by (OK).
The antenna voltage is displayed and should be followed by (OK). The tuning
value is displayed. The graph should show a dot in the middle band and be
followed by (OK).
Displays the levels of interference being detected. The noise level should be in the
lower part of the graph.
Displays the reads per minute for the current location of the tag.
The panel reader software version.
You can change the language displayed on the panel reader's LCD.
Bluetooth
enabled devices.
once
.
each time it is read
.