Maintenance; Annual Maintenance; Membrane Replacement - Watts Premier RO-PURE Manual De Instalación, Operación Y Mantenimiento

Sistemas de ósmosis inversa de 4 fases
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Maintenance

WARNING
!
For proper performance and to help avoid exposure to
contaminants, this system must be installed, maintained and
operated as specified in this Manual.
It is important to change out your filters at the recommended
intervals as indicated in this system manual. When replacing
the filter elements, pay special attention to any cleaning in-
structions. Should you have any further questions please refer
to our web site at www.premierh2o.com or call our customer
service department at 1-800-752-5582.
With proper installation and maintenance, this system will
provide you with high quality water for years to come. All
of Premier's water enhancement products are rigorously
tested by independent laboratories for safety and reliability.
If you have any questions or concerns, please contact our
customer service department at 1-800-752-5582 (outside USA
480-675-7995) or refer to our on-line troubleshooting guide at
www.premierh2o.com.
NOTICE
If your RO system is connected to a refrigerator / ice maker,
you must turn off the connection to that appliance during the
system maintenance.
NOTICE
The following is a minimum replacement schedule – More
frequent filter replacement may be required depending on
your particular water conditions and use.
6 Month Maintenance
*Order filters by calling 1-800-752-5582 or buy online at
www.premierh2o.com.
Replace: (1) Sediment Filter
(1) Carbon Block Filter

Annual Maintenance

Replace: (1) Sediment Filter
(1) Carbon Pre-Filter
(1) Carbon Post-Filter
NOTICE
This is a good time to check the air pressure in your storage
tank. For instructions please see page 9.
Flush first tank full after completing the annual maintenance.
Step A – Place a towel under the RO module to catch any excess
water that drips out from the filters during the changeover.
Step B – To make the removal of the
filter housings easier, the heads
and housings may be lifted up
to 90° as shown in the pictures
to the right.
To remove a filter cartridge:
Push & hold the button on the
valve head above the filter. Pull
cartridge downward (from
the head) to remove. Release
button and discard old filter.
Red Label P/N: WP105311
Yellow Label P/N: WP105351
Red Label P/N: WP105311
Yellow Label P/N: WP105351
Blue Label P/N: WP105341
Step C – Make sure to remove the cap off of the new replacement
filter.
To install a filter cartridge: Remove the seal cap and
insert the cartridge into the valve head until you hear an
audible "click" (the button does not need to be pressed to
install new filters).
To reset the electronic monitor during replacement of filters,
simply slide out the battery from the base of the faucet
and reinsert.

Membrane Replacement

Includes: (1) RO Membrane
Membranes have a life expectancy between 2 and 5 years, de-
pending on the incoming water conditions and the amount the
RO system is used. This reverse osmosis membrane is critical for
effective reduction of total dissolved solids (TDS). The product water
should be tested periodically to verify that the system is performing
satisfactorily.
Normally, a membrane would be replaced during a semiannual or
annual filter change. However, if at any time you notice a reduction in
water production or an unpleasant taste in the reverse osmosis wa-
ter, it could be time to replace the membrane. Premier recommends
replacing the membrane when TDS reduction falls below 75%.
8
(50 GPD Green Label P/N: WP105331)

Publicidad

Tabla de contenido
loading

Tabla de contenido