Actuator with changeover relay output 16 A - 2 modules.
CHARACTERISTICS.
• Rated supply voltage: BUS 29 V
• Input: 10 mA
• Changeover relay output
• Controllable loads at 120-230 V~ (contact NO):
- resistive loads:
16 A (20.000 cycles)
- incandescent lamps: 10 A (20.000 cycles)
- fluorescent lamps and energy saving lamps: 1 A (20.000 cycles)
- electronic transformers: 4 A (20.000 cycles)
- ferromagnetic transformers: 10 A (20.000 cycles)
• Controllable loads at 120-230 V~ (contacts NO and NC):
- motors cos ø 0.6: 3,5 A (100.000 cycles)
• Terminals:
- TP bus
- relay contacts (C, NC, NO)
CONFIGURATION.
FOR THE OPERATIONS OF INSTALLATION AND CONFIGURATION, SEE
THE By-me SYSTEM INSTRUCTIONS MANUAL ATTACHED TO THE
COMFORT CONTROL UNIT.
• Functional blocks: 1
• Selecting the functional block (configuration): during group creation, when the
control unit requires pressing the device button:
- press the button, the LED will light up;
- with the LED on, the control unit will configure the functional block; at the end of
this operation the LED will go out.
PARAMETERS.
• one- or two-position stable operation;
• on delay and off delay: a value between 0 and 200 gives the time in seconds,
a value between 201 and 250 gives the time in minutes (for example 201 = 1
minute, 202 = 2 minutes, etc.);
One-position stable operation.
On delay: delay in closing the NO contact of the relay from receiving the close
command.
Off delay: time for which the relay has the NO contact closed.
Two-position stable operation.
On delay: delay in closing the NO contact of the relay from receiving the ON com-
mand.
Off delay: delay in opening the NO contact of the relay from receiving the OFF
command.
Note.
If a group is created with a number of relays in one-position stable mode, set for
all the same on and off delays and do not insert any other types of actuator in the
same group; in this way, it is possible to have the status of the one-position stable
relay indicated on the control button. For special requirements it is possible to use
the group depth (for example to switch on two-position stable relays or dimmers
with a single button).
• Default parameters: relay set on two-position stable operation with null on and off
delay.
SCENARIOS
The actuator can belong to up to 4 different scenarios and, for each scenario, save
the status to retrieve when activating the scenario.
Viale Vicenza, 14 - 36063 Marostica VI - Italy
Tel. +39 0424 488 600 - Fax (Italia) +39 0424 488 188
Fax (Export) +39 0424 488 709
www.vimar.com
Plana
14535

FRONT VIEW

Arké
Eikon
A
B
Idea
Plana
A
B
Caption:
A: led
B: configuration button
FIGURE 1.
ON delay
ON delay
ON
Control
ON
ON delay
OFF delay
Control
Control
ON
OFF
INSTALLATION RULES.
Installation should be carried out observing current installation regulations for electri-
cal systems in the country where the products are installed.
The feeding circuit of the relay output must be protected against overloads by a
device, fuse or automatic circuit breaker, with rated current not higher than 16 A. For
further instructions, please see the manual attached to the control panel.
CONFORMITY.
LV directive
EMC directive
Standard EN 50428.