Abnormal Operations Mode; Backlight; Maintenance; Technical Specifications - GOAL ZERO 10 AMP Guia Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 24
Abnormal Operation - LED Indication
Solar panel
LCD Display
Abnormal Mode
Solar panel weak
Solar panel reverse
connection
Solar panel over
voltage (> 26.5V)
Solar panel
LCD
Abnormal Mode
Display
Battery
disconnected or
less than 3.0V
Battery reverse
connection
Battery over
voltage than >
17.5V
Battery
temperature over
65°C
Solar panel
LCD Display
Abnormal Mode
The controller
over temperature
protection
12
LED Indication
LCD Backlight
Flash
Flash
Flash
LED Indication

Backlight

Flash
Flash
Flash
Flash
Flash
Flash
Flash
Flash
LED Indication
LCD Backlight

Maintenance

The controller is maintenance free. If the connection wire is damaged or loosed, please
replace the new wires or tighten the screws. The case should be cleaned occasionally with
dry cloth.
ON

Technical Specifications

Flash
Electrical Parameters
Rated solar panel amps GZ-10
Flash
Normal input Solar cell array voltage
Max. solar cell array voltage (output has no load)
LCD
The controller lowest operating voltage at solar or
battery side
Charging characteristics
Start Voltage at 25°C
Flash
Flash
Charge Voltage at 25°C
Flash
Equalizing voltage at 25°C
Float voltage at 25°C
Flash
Battery temperature compensation coefficient
Protection
Against reverse polarity or short circuit
No reverse current from battery to solar at night
Over temperature protection during charging
Flash
Parameter
10A
15-22V
25V
8V Minimum
3-10V
LTO battery-14.0V
Gel battery-14.1V
LiFePO4 battery-14.4V
AGM battery-14.4V
WET battery-14.7V
Calcium battery-14.9V
WET or Calcium battery-15.5V
Gel, AGM, WET, Calcium batteries - 13.6V
LTO and LiFePO4 – 13.4V
-24 mV/°C
65°C
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

3700-149

Tabla de contenido