Important! The fitting must be installed, flushed and
tested after the valid norms.
Operation
The mixer is activated by lifting the lever handle.
Turning to the left = warmer water,
turning to the right = cooler water.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 0,3 MPa:
Hansgrohe single lever mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
To adjust the hot water limiter on single lever mixers,
please see page 8.
No adjustment is necessary when using a continuous flow
water heater.
Fault
Mixer stiff
Mixer dripping
Hot water temperature too low, no
cold water.
Instantaneous water heater starts up
when cold water is selected.
1
English
Spare parts (see page 4)
1
2
3
4
5
6
7
8
9
max. 1 MPa
10
0,1 - 0,5 MPa
11
1,6 MPa
12
13
max. 80° C
14
65° C
15
ca. 32 l/min
16
17
18
19
20
21
22
23
24
25
XXX = Colors
000 chrome plated
400 white/chrome plated
820 brushed nickel
880 satin chrome
Cause
- Cartridge defective, calcified
- Cartridge defective, sedimentation
- Hot water limiter incorrectly set
- Crossflow
handle Talis E²
screw cover
handle Metropol S
handle Focus S
handle Talis S / Talis S²
handle Metris S
handle Talis Classic
handle Focus E²
handle PuraVida
handle Metris Classic
face plate
face plate PuraVida
face plate Metris Classic
flange
fixing screw
sub plate
nut
cartridge cpl.
locking screw for handle
seal
screw M5 x 20 (4)
noise reduction
extension 25 mm
extension 22 mm
extension 22 mm
Remedy
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Exchange seal (20)
Exchange O-ring
31692000
96338000
14895XXX
31793000
32096000
31093000
14193XXX
98532000
95273XXX
31294XXX
98792XXX
95276XXX
95412XXX
98790XXX
96454000
98793000
98796000
92730000
95140000
95008000
96525000
94073000
13595000
13597XXX
15597000