Safety Notes; Installation Instructions; Technical Data; Symbol Description - Hansgrohe Focus 31940000 Modo De Empleo/Instrucciones De Montaje

Ocultar thumbs Ver también para Focus 31940000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 6

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
• The diverter (type HC) installed in the bath mixer is
designed as an anti-retraction device. For this reason,
the lower edge of the diverter must be at least 250
mm above the highest possible dirty water level.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
Instantaneous heater didn't work
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
Cause
- check valve hasn't moved back
- Shower filter seal dirty
- Cartridge defective, calcified
- Cartridge defective
- Hot water limiter incorrectly set
- Flow limiter in handshower isn't
removed
- Shower filter seal dirty
- check valve hasn't moved back
Assembly see page 31
• Safety against backflow
• The product is exclusively designed for drinking water!

Symbol description

Do not use silicone containing acetic acid!
Adjustment (see page 33)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Operation (see page 35)
Dimensions (see page 36)

Flow diagram

(see page 37)
Spare parts (see page 38)
Maintenance (see page 40)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Cleaning (see enclosed brochure)
Test certificate (see page 40)
Remedy
- Exchange check valves
- Clean filter seal between shower
and hose
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Remove flow limiter
- Clean filter seal between shower
and hose
- Exchange check valves

Publicidad

Tabla de contenido
loading

Tabla de contenido